Similar Projects
Replacement of AHU 9 - Halifax Health 4th Floor CVOR
Bidding
Daytona Beach, FL 32116

Halifax Health T-Zone Air Handling Unit Replacement
Post-Bid
Daytona Beach, FL 32100

Seabreeze High School HVAC, Ceiling and Lighting Building 1
Post-Bid
Daytona Beach, FL 32118

FDOT HVAC Install: Sneads WB Weigh Station
Results

Lakeside HVAC and Ceiling Replacement
Results
Less than $400,000 est. value
Port Orange, FL 32129

HVAC and Mechanical Products
Term Contract
Post-Bid

Direct Replacement of 60 Ton Chiller and Two 30 Ton Air Handlers
Results
Daytona Beach Shores, FL 32116

Seabreeze High School HVAC Renovation Building 2
Post-Bid
Daytona Beach, FL 32118

Emergency Vehicle Exhaust Extraction System
Term Contract
Results
Less than $80,000 est. value
De Land, Lake Helen, New Smyrna Beach, FL 32169

Gemini ES CEP Upgrades
Post-Bid
Melbourne Beach, FL 32951

Peabody Lobby HVAC Replacement
Results
Less than $45,000 est. value
Daytona Beach, FL 32114

Pine Ridge High School HVAC Renovation
Post-Bid
Daytona Beach, Deltona, FL 32116

Upgrade CEP Controls and AHU Dampers - New Smyrna Beach High
Results
Less than $520,000 est. value
New Smyrna Beach, FL 32168

HVAC Condensing Unit Replacement
Results
Less than $450,000 est. value
Daytona Beach, FL 32114

Indian River Elementary School - Replace Chiller Building 7
Results
Less than $150,000 est. value
Edgewater, FL 32141

Last Updated 06/15/2020 02:08 PM
Project Title

Ultraviolet-C Germicidal Air Handler Treatment Systems

Physical Address View project details and contacts
City, State (County) FL   (Volusia County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $296,545
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The County of Volusia is seeking to improve its HVAC systems efficiency, occupant comfort, and indoor air quality. Through the adoption of an Ultraviolet-C (UVC) treatment systems, the County of Volusia will benefit from microbial disinfection of air handler interior surfaces, particularly cooling coils, to prevent biological growth from becoming established. Controlling the proliferation of microorganisms in HVAC systems is essential for optimal coil heat transfer, lower pressure drop across the coil, and reduced air handler speed which all contribute to long-term energy savings and reduced HVAC system maintenance costs. This project will entail the installation of UVC germicidal air handler treatment systems for sixty three (63) air handling units located in six (6) different Volusia County buildings. Currently, these building do not utilize UVC Treatment systems and this will be a complete up fit. All UVC systems shall be provided by a single manufacturer. Fresh-Aire UV is the basis of design. Control Systems Specialist, Inc. (CSSI) is the County of Volusia’s contractor for building automation. Contractor shall coordinate any integration or interlocking of devices with CSSI.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents