Similar Projects
Addition and Alterations to Fire Station Building 2090
Addition
Post-Bid
Camp Shelby, MS

Fire Station 3 Renovations and Repairs
Renovation
Results
$62,256 est. value
Starkville, MS 39759

New Sheriff Building & Detention Center Improvements
New Construction, Renovation
Design
Oxford, MS

City of Collins - Police Station Addition and Renovation
Renovation, Addition
Results
Collins, MS

Basin Volunteer Fire Department Hurricane Zeta Remediation Work
New Construction - 2,360 SF
Post-Bid
Lucedale, MS 39452

DLO Fire Station
New Construction
Design
Forest, MS

New Sheriff Office Building
New Construction - 6,968 SF
Post-Bid
Fulton, MS

New Sheriffs Building & Detention Center Improvements
New Construction, Renovation
Design
Oxford, MS

City of Senatobia - Police Station Renovation
Renovation - 6,628 SF
Results
$663,834 est. value
Senatobia, MS 38668

Lamar County Fire Training Facility and EMA Dry Storage Warehouse
New Construction
Results
Purvis, MS

Reported 04/06/2022 12:00 AM
Project Title

Desoto County Sheriff's Department ICAC Renovations

Physical Address View project details and contacts
City, State (County) Hernando, MS 38632   (DeSoto County)
Category(s) Government/Public
Sub-Category(s) Fire/Police Station
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from County Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The Project consists of the construction of a new addition to the existing Sheriff’s Department facility located at 3091 Industrial Dr W, Hernando, MS 38632. The building addition includes a new concrete foundation, concrete masonry construction, bar joist roof structure, steel decking, and single ply roofing system. New extensions on the fire suppression system, electrical system to new sub-panel, and new HVAC system for the addition areas. Interior materials include steel stud constructed partitions, sound rated partitions, carpet, lvt flooring, porcelain tile in the restrooms, and new ceilings and lighting. The fire alarm system is to be incorporated into the existing system, see electrical. Exterior materials include brick, two types of exterior metal panel, and single ply roofing system. The addition is to be structurally isolated from the original building, see structural. The addition was designed to have minimal impact on existing spaces inside the existing building. Parking modifications are required for the building addition. New sidewalks, new susbsurface downspout drainage, new gas supply extension, and new patch areas of asphalt are required for a finished site incorporation of the building addition.

Details

Division 02 - Existing Conditions.
Division 03 - Concrete, Concrete Forming and Accessories, Concrete Forming, Cast-in-Place Concrete.
Division 04 - Masonry, Unit Masonry.
Division 05 - Metals, Structural Metal Framing.
Division 06 - Wood, Plastics, and Composites, Rough Carpentry, Finish Carpentry.
Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection, Weather Barriers.
Division 08 - Openings, Doors and Frames, Metal Doors and Frames, Wood Doors, Plastic Doors, Specialty Doors and Frames, Panel Doors, Multi-Leaf Vertical Lift Doors, Windows.
Division 09 - Finishes, Plaster and Gypsum Board, Tiling, Ceilings, Flooring, Acoustic Treatment, Painting and Coating, Painting, High-Performance Coatings.
Division 10 - Specialties, Signage, Compartments and Cubicles, Toilet Compartments, Shower and Dressing Compartments, Toilet, Bath, and Laundry Accessories, Emergency Aid Specialties, Fire Protection Specialties, Lockers, Wardrobe and Closet Specialties, Flagpoles, Flags and Banners.
Division 11 - Equipment, Unit Kitchens.
Division 12 - Furnishings, Countertops, Rugs and Mats.
Division 14 - Conveying Equipment, Slide Pole Systems, Firehouse Slide Poles.
Division 21 - Fire Suppression, Facility Fire-Suppression Water-Service Piping, Fire-Department Connections, Fire Pumps.
Division 22 - Plumbing, Instrumentation and Control for Plumbing, Facility Water Distribution, Facility Storm Drainage, Plumbing Equipment, Plumbing Fixtures, Emergency Plumbing Fixtures, Drinking Fountains and Water Coolers.
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Piping and Pumps, HVAC Air Distribution.
Division 26 - Electrical, Power Distribution Units, Interior Lighting, Emergency Lighting, Exit Signs, Exterior Lighting.
Division 27 - Communications, Structured Cabling, Call Management, Distributed Audio-Video Communications Systems.
Division 28 - Electronic Safety and Security, Electronic Detection and Alarm, Fire Detection and Alarm.
Division 31 - Earthwork, Clearing and Grubbing, Grading, Soil Treatment.
Division 32 - Exterior Improvements, Bases, Ballasts, and Paving, Flexible Paving, Asphalt Paving, Rigid Paving, Concrete Paving, Curbs, Gutters, Sidewalks, and Driveways.
Division 33 - Utilities, Water Utilities, Sanitary Sewerage Utilities, Storm Drainage Utilities.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents