Similar Projects
Last Updated | 11/11/2020 11:12 AM |
Project Title | Waste Water Treatment Plant CAFB |
Physical Address | View project details and contacts |
City, State (County) | Albuquerque, NM 88103 (Bernalillo County) |
Category(s) | Sewer and Water |
Sub-Category(s) | Water Treatment Plant |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The Contractor shall provide all management, tools, supplies, parts, equipment, certified personnel and labor, necessary to ensure that wastewater treatment plant (WWTP) services are performed at Cannon AFB (CAFB), in accordance with all federal, state, and local laws and regulations. WWTP operations shall be conducted in order to provide continuous, cost effective, and efficient treatment of all wastewater delivered to the facility. This is for the operation, maintenance and repair of all equipment at the WWTP including, but not limited to, a manual bar screen, a mechanical bar screen, two influent pump stations (one is currently out of service), three Sequencing Batch Reactors (SBR) with total capacity of approximately 1.5 million gallons per day (MGD), one aerobic digester, one chlorine contact chamber, two Screw Pumps, one Huber Grit and Grease Unit, 13 flow meters, grit and sludge drying beds, one Hi-Tech Grit and Grease Unit, one Auger Monster®, one Raw Wastewater Storage Basin with pump, one Effluent Storage Basin with three pumps, one AquaDisk® Filter Unit with cloth media, six four SBR aeration blowers (one backup), two digester aeration blowers, six chemical pumps, SCADA system, and one SolarBee. The plant shall operate 24 hours a day, 7 days a week. Such operations shall include general operation of plant equipment, valves and piping, sampling and lab analysis, waste and effluent disposal, and other related services. Facility operations and effluent discharge practices shall comply with all applicable federal, state, and local regulatory standards, including the New Mexico discharge permit requirements. If the discharge permit lapses, expires or is terminated for any reason, the Contractor shall continue to operate the WWTP in accordance with permit requirements unless directed by the Contracting Officer. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Project Documents |
![]() Engineered Spec Sheet ![]() Architectural Plans ![]() Other Documents |