Similar Projects
Fort Hood Fuel Facility Replacement
Design
$25,000,000 to $100,000,000 est. value
Fort Hood, TX 76544

Fleet Fuel Rehabilitation
Bidding
$1,900,000 est. value
College Station, TX

Polyethylene Storage Tanks for 50% Caustic Soda
Bidding
Corpus Christi, TX

Hydropneumatic Tank Replacements
Post-Bid
Conroe, TX 77385

Atmos Energy Gas Distribution Line for New Sherman High School
Post-Bid
Sherman, TX 75090

Pump House Above Ground Tanks Installation
Results
$498,745 est. value
Grand Prairie, TX 75051

Installation of AST System
Results
$435,650 est. value
Terrell, TX

Fuel Stations, Multiple Locations in Abilene District
Bidding
$975,000 est. value
Abilene, TX 79601

Brewster Fuel Tank Relocation
Post-Bid
Edinburg, TX 78539

Precast Fuel Storage Tanks
Results
Angleton, TX

Annual Contract for Underground Fuel Storage Tank Services
Bidding
San Antonio, TX 78275

Installation of Dual 10,000 Gallon Orthoresin Tanks for Abilene Txdot Locations
Post-Bid

Compressed Natural Gas (CNG) Upgrade Facility & Related Work (Pp-21812971)
Results
Less than $300,000 est. value
San Antonio, TX 78249

Fuel Island Expansion at Bayport Container Terminal
Bidding
Seabrook, TX 77586

Maintenance and Repairs of Fuel Dispensers and Automated Network Services
Term Contract
Post-Bid
Houston, TX 77002

Reported 05/01/2021 12:00 AM
Project Title

JSBA Fire Suppression Pump Engine Repair

Physical Address View project details and contacts
City, State (County) Randolph Air Force Base, TX 78150   (Bexar County)
Category(s) Sewer and Water
Sub-Category(s) Fuel/Chemical Tanks and Lines
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Repair Diesel pump engine #1, #2 and #3. Remove and replace identified damaged or non-operational parts. Flush fuel lines and remove old diesel fuel from the three fuel tanks. The proposed scope of work shall include the following repairs as listed in Appendix 1. All parts and consumables used to complete the repairs identified in Appendix 1 shall be new and IAW manufacturers’ recommended procedures. The repairs shall be conducted in accordance with the component manufacturer’s mandatory and/or recommended procedures. At the completion of repairs, the contractor shall fill the external diesel tanks. REMOVE AND DISPOSE 1. Remove and dispose the old non operational parts for Engines 1, 2, 3. 2. Remove and dispose all used oil, antifreeze in all diesel engines. 3. Remove and dispose all old diesel fuel in the fuel lines and the 3 external fuel tanks

Details

Division 02 - Existing Conditions, Subsurface Investigation.
Division 03 - Concrete, Concrete Reinforcing, Cast-in-Place Concrete.
Division 05 - Metals, Structural Metal Framing, Metal Decking.
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Facility Fuel Piping, Facility Fuel-Storage Tanks.
Division 31 - Earthwork, Clearing and Grubbing, Grading.
Division 32 - Exterior Improvements, Fences and Gates.
Division 33 - Utilities, Storm Drainage Utilities.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents