Similar Projects
Reported | 05/12/2020 12:00 AM |
Project Title | Sources Sought Notice for Bldg 620 Whole Building Repair Project, United States Military Academy, West Point, NY |
Physical Address | View project details and contacts |
City, State (County) | West Point, NY 10996 (Orange County) |
Category(s) | Residential |
Sub-Category(s) | Dormitory |
Contracting Method | Competitive Bids. |
Project Status | Accepting Letters of Interest |
Bids Due | View project details and contacts |
Estimated Value | $25,000,000 to $100,000,000 |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | SCOPE OF WORK: Building 620 was built in 1908 and is used as an existing dormitory. The building is showing signs of age. Major building systems and components are failing due to their age and deterioration from continual use. Various retrofit repairs have been made in the past, but the facility lacks the means to support modern living standards. The building’s essential elements are in need of repair to prevent further failure, continued deterioration, and avoid potential future hazards. The project entails the full renovation of the unaccompanied personnel housing (UPH) Barracks, building 620, and its supporting facilities including surrounding paving, landscape, and utilities infrastructure tie-ins. The current barracks facility has 75 Barracks Rooms and an administrative wing totaling 5,959 Gross Square Feet (GSF). The entire building is 54,237 GSF. Building interior improvements shall replace sub- standard design, life/safety, and energy conservation issues that are no longer comply with current industry standards and accommodate modern living conditions. Improvements shall also entail the replacement of furnishings and finishes to address the deteriorating condition of furniture; interior walls and insulation; doors and door hardware; interior wall finishes; finish floors coverings; ceiling height and materials; toilet room finishes and fixtures. Building exterior renovations shall address failing and or deteriorating systems including water infiltration repairs; partial structural roof system replacement at flat roof; new roofing insulation and waterproofing at flat roof portion of building; new roof metal work including gutters and flashing at slate roof; repair slate roof; window replacement; repair of exterior wall. Hazardous building material such as asbestos, lead, and radon may exist and shall be abated. Mildew and mold that has formed due to water infiltration or improper ventilation shall also be abated. All renovation to correct building failures shall impact only non-historic components or systems. Coordination with SHPO and local historic preservation agencies as well as observance of preservation policies shall be observed. Mechanical/Electrical/Plumbing (MEP) improvements shall correct failures and aging systems through complete replacement including: fire suppression and water supply systems; fire alarm and mass notification system; fire detection, protection, monitoring, and controls; heating and ventilation systems; plumbing systems; electrical systems; telecommunication and cabling systems; security closed circuit television (CCTV); access control card access systems; public address systems; time clock systems; cable television systems; and distributed antenna systems (DAS). Supporting facility improvements shall address utility infrastructure, hardscape and landscape features, and site security features within the project site limits. These include replacement of all deteriorated and/or under-capacity lateral utility lines including domestic water, fire protection water, heating hot water, sewer, natural gas, electrical and storm sewer systems back to main shutoff valve, manhole, and pad mounted transformer; the replacement of all walkways, replacement of damaged trees, shrubs, groundcover, and lawn; replacement of damaged curbing, steps, ramps, railings, and other hardscape features; installation of new tree-well grates, benches, trash receptacles, and removable bollards (if necessary). |
||||||||||||||||||||||||||||||||||||||
Details | 1 Dormitory, Approximately 54,237 SF Renovation.
|
||||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |