Similar Projects
Last Updated | 05/13/2022 02:48 PM |
Project Title | Palm Beach County Desilting Primary - Drainage Repair |
Physical Address | View project details and contacts |
City, State (County) | FL (Palm Beach County) |
Category(s) | Heavy and Highway |
Sub-Category(s) | Shoreline/Erosion/Drainage |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $200,000 |
Plans Available from | State Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Contract Consists Of Supplying All Equipment, Materials, Labor And Incidentals Necessary To Clean, Video And Repair Leaks In The Drainage System On State Roads In Palm Beach County. Section 0001 Clean Drainage Structures (Lf) 0430-821- 23 Cleaning & Sealing Existing Pipe Joint, 15" Storm Sewer Ea 10.000 0430-821- 25 Cleaning & Sealing Existing Pipe Joint, 18" Storm Sewer Ea 10.000 0430-821- 29 Cleaning & Sealing Existing Pipe Joint, 24" Storm Sewer Ea 10.000 0430-821- 33 Cleaning & Sealing Existing Pipe Joint, 30" Storm Sewer Ea 10.000 0430-821- 38 Cleaning & Sealing Existing Pipe Joint, 36" Storm Sewer Ea 10.000 0430-821- 40 Cleaning & Sealing Existing Pipe Joint, 42", Storm Sewer Ea 5.000 0430-821- 41 Cleaning & Sealing Existing Pipe Joint, 48", Storm Sewer Ea 5.000 0430-821- 42 Cleaning & Sealing Existing Pipe Joint, 54", Storm Sewer Ea 10.000 0430-821- 43 Cleaning & Sealing Existing Pipe Joint, 60", Storm Sewer Ea 10.000 0430-821- 61 Cleaning & Sealing Existing Pipe Joint, >60", Storm Sewer Ea 5.000 0430-950- Desilting Concrete Box Culvert Cy 10.000 0433- 1- Chemical Grout Repair, Manhole / Inlet Ea 72.000 e101- 72- Mobilization (Emergency Response) Ea 10.000 e425- 73- 1 Cleaning Manholes And Inlets (Mechanical) Ea 454.000 e430- 94- 1 Desilt Pipe, 0 To 24" Lf 4,000.000 e430- 94- 2 Desilt Pipe, 25-36" Lf 4,000.000 e430- 94- 3 Desilt Pipe, 37-48" Lf 4,000.000 e430- 94- 4 Desilt Pipe, 49-60" Lf 1,000.000 e430- 94- 5 Desilt Pipe, 61" Or Greater Lf 100.000 e431- 1- 11 Pipe Liner, Spray Application, Lf 300.000 e431- 1- 12 Pipe Liner, Spray Application, Lf 300.000 e431- 1- 21 Pipe Liner, Cured In Place, Lf 50.000 e431- 1- 22 Pipe Liner, Cured In Place Lf 50.000 e431- 1- 23 Pipe Liner, Cured In Place, Lf 1.000 e431- 1- 25 Pipe Liner, Cured In Place, And Greater Lf 1.000 e432- 4- Storm Sewer Inspection (Video Camera) Lf 14,940.000 |
||||||
Details |
|
||||||
Bidder's List | View project details and contacts | ||||||
Prospective Bidders | View project details and contacts | ||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |