Similar Projects
Z2DZ--Renovate and Replace Pharmacy AHUs
Design
$1,000,000 to $5,000,000 est. value
Durham, NC 27705

Equipment Operation and Maintenance for The Central Energy Building, Naval Health Clinic, MCAS Cherry Point Nc
Design
Cherry Point, NC

Union West Regional Library Ceiling
Bidding
Indian Trail, NC 28079

Replacement and Installation of a 10 Ton HVAC Split System
Bidding
Granite Quarry, NC 28146

HVAC Replacements
Post-Bid
Salisbury, NC

20 Ton Air-Cooled Chiller
Post-Bid
Greensboro, NC 27412

56--Upgrade OA & Exhaust Fans Phase II(VA-19-00005148)
Demolition
Results
$500,000 to $1,000,000 est. value
Durham, NC 27705

Frank Porter Graham Elementary School - Intermediate & Media Buildings Hvac Replacement
Results
Chapel Hill, NC

Ronald Wilson Reagan High School HVAC Replacement
Design
Pfafftown, NC 27040

HVAC Maintenance and Water Treatment Service
Term Contract
Bidding
Lumberton, NC 28360

PC Air Units
Post-Bid
Charlotte, NC 28208

HVAC Maintenance Contract
Term Contract
Results
Less than $713,590 est. value
Dunn, Erwin, Lillington, Spring Lake, NC 27546

Durham City Hall HVAC and Electrical Renovations
Post-Bid
Durham, NC

Hall Building Mechanical and Electrical Upgrade
Results
Kenansville, NC

Design Build - Indoor Pool Dehumidification System
Post-Bid
Waynesville, NC 28786

Reported 12/18/2020 12:00 AM
Project Title

CTC Computer Room Air Conditioner

Physical Address View project details and contacts
City, State (County) Archdale, NC 27263   (Randolph County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Request for Proposals (RFPs)
Bids Due View project details and contacts
Estimated Value
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

1. Removal of existing Liebert Split System computer room Air Conditioning unit including the fan coil unit, condensing unit, and associated refrigerant and condensate piping. 2. Install one (1) New Liebert Split System Computer Room AC unit including fan coil unit, condenser, and associated refrigerant and condensate piping. Alternate #1. Remove Existing Liebert Split-System Computer Room AC unit including fan coil unit, condensing unit, and associated refrigerant and condensate piping. 2. Install one (1) New Daikin or Equal Split-System Heat Pump and Two (2) New Daikin or Equal Split-System AC units including ceiling mounted cassettes, refrigerant piping, condensate piping, remote controllers, and control wiring

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents