Similar Projects
Indefinite Delivery/Indefinite Quantity Electronic Security Systems (ESS) 7th Generation
Term Contract
Design
Less than $675,000,000 est. value

PME9 Switchgears and Ground Sleeves
Alteration
Bidding
Apex, NC

Light Fixtures, Poles, and Anchor Bases - Pleasant Park
Alteration
Bidding
Apex, NC

Generator Replacement - Lockhart, Hardee's, Lonesome Wind, Southland Pump, Hometown, and Bent Tree Pump Stations
Post-Bid
Raleigh, NC 27601

NCDOA Executive Resident Kitchen Hood Systems
Post-Bid
Raleigh, NC 27601

Construction Manager at Risk - Electrical Distribution Upgrade Project
Results
Less than $58,800,000 est. value
Raleigh, NC 27695

Emergency Generator Preventative Maintenance
Term Contract
Results
Raleigh, NC 27610

Electrical Distribution Upgrade
Alteration
Construction
$47,211,000 est. value
Raleigh, NC

New Emergency Generator - RPD(Raleigh Police Department)
Alteration
Bidding
$300,000 est. value
Raleigh, NC 27610

Raleigh Municipal Building Critical Equipment Replacement
Post-Bid
Raleigh, NC 27601

Town Hall Generator
Term Contract
Results
Less than $296,200 est. value
Cary, NC 27513

Maintenance Contract for Transfer Switches State Government Complex
Post-Bid
Raleigh, NC

Construction of HVAC and Electrical Renovations for Rock Quarry Road Auxiliary Services
Results
Raleigh, NC 27610

Service Agreement for Nitrogen/Hydrogen Generators
Post-Bid
Greensboro, Raleigh, NC 27603

Ozone Cooling Pipe Water Modifications
Term Contract
Results
Raleigh, NC 27614

Last Updated 05/31/2022 02:22 AM
Project Title

Distribution Transformers 25 KVA Single Phase UG

Physical Address View project details and contacts
City, State (County) Wake Forest, NC   (Wake County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

All transformers are to be high-side rated 13,200 volts for use on a 22,860/13,200 volt system. 1. Rated 13,200 Volts for use on a 22,860/13,200 Volt Grounded Wye Electric System. 2. Oil Filled. 3. Primary Loop Feed. 4. Dead Front Design. 5. 65 Degree C Rise, 60 Hertz. 6. Two (2) High Voltage Universal Bushing Wells. 7. Low Voltage Threaded Stud Bushings. 8. High Voltage "Bayonet" Fusing. 9. Low Voltage Breaker. 10. No High Voltage Taps. 11. Liting Bolts. 12. Padlock Provisions. 13. Penta Head Captive Bolt. 14. Tamper Proofing Guards. 15. Accessory Parking Stand (High Voltage), Two (2). 16. Automatic Pressure ReliefValve with Internal Fault Indicator. 17. Low Voltage Grounding Provisions. 18. Tank Ground Provisions. 19. Oil Fill/Level Plug. 20. Oil Drain Plug. 21. Name Plate. 22. Non-PCB with "Non-PCB" Sticker. 23. KVA Rating Listed on Side ofTransformers in Numbers Not Less than One Inch (1") in Height. 24. Delivered on wooden pallet.

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents