Similar Projects
Last Updated | 06/22/2023 12:34 AM |
Project Title | Piston Ring Replacement, Hydraulic Gates, Blackwater Dam |
Physical Address | View project details and contacts |
City, State (County) | Webster, NH 03303 (Merrimack County) |
Category(s) | Heavy and Highway |
Sub-Category(s) | Dam/Tunnel, Site Development |
Contracting Method | Competitive Bids |
Project Status | Bidding, Construction start expected July 2023 |
Bids Due | View project details and contacts |
Estimated Value | $250,000 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Goals for minority participation for each trade 3.6% Goals for female participation for each trade 6.9% THE WORK CONSISTS OF: The goal of this project is to minimize the ongoing hydraulic fluid slip, which is consequently allowing the operating gates to drift from their specified height. The project includes, but is not limited to, the removal and replacement of the middle piston ring for each gate (three service, three emergency) and replacement with a new hydrolysis-resistant polyurethane piston seal manufactured to operate within the specified hydraulic fluid type, pressure, & temperatures. The Contractor shall note that only one gate at a time may be worked on until the repair work is complete. The outlet works are incorporated within the spillway and consist of three conduits located through the deep section of the spillway adjacent to the non-overflow section. Access to the gates is by a stairway from the equipment operating room and then through a gallery. Flow through each conduit is controlled by a hydraulically operated gate; additionally each gate is also equipped with a hydraulically operated emergency gate. All gates are operated by hydraulic pumps located in the equipment room. Flow through the conduit passes back into the natural river channel. During normal operation all gates are maintained at a 3-foot opening. Air vents are provided for both the service and emergency gates. There is an onsite 2-ton monorail hoist located in the operating room that will be available for use; however, the Contractor shall be required to provide an annual inspection certificate and conduct operational testing prior to use. Existing anchor points are located above the gate cylinders in the gallery. Similar to the monorail hoist, the Contractor shall be required to conduct operational testing prior to use. The gate chamber (gallery) is considered a Non-Permit Required Confined Space. If work execution in the gate chamber creates an atmospheric hazard, the gate chamber will be reclassified as a Permit-Required Confined Space. The magnitude of construction is between $100,000 and $250,000 This procurement is set-aside for small business vendors. The applicable NAICS code is 237990 with a Small Business Size Standard of $45 Million. ALL VENDORS MUST HAVE AN ACTIVE REGISTRATION IN SAM.GOV AT THE TIME OF SUBMISSION IN ORDER TO BE CONSIDERED. ANY VENDOR THAT DOES NOT HAVE AN ACTIVE SAM.GOV REGISTRATION WILL BE REJECTED AS NON RESPONSIVE. Please Direct Questions to Jennifer M. Samela at (978) 318-8324 or Jennifer.m.samela@usace.army.mil. Any Information Received at the Site Visit Which Conflicts With This Solicitation Should Be Brought to the Attention of Jennifer M. Samela. The Solicitation and Resulting Contract Shall Be the Governing Document in All Cases. *The value for this project is based on a financial range. The value is listed as the highest possible cost from the range provided by a stakeholder or official project document. |
||||||
Details |
|
||||||
Bidder's List | View project details and contacts | ||||||
Prospective Bidders | View project details and contacts | ||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |