Similar Projects
CVMF Complex Storm and Sanitary Sewer Improvements
Infrastructure
Bidding
$379,000 est. value
Rochester, NY 14606

SUNY Purchase Stormwater Management Infrastructure Rehabilitation
Infrastructure
Bidding
$1,000,000 to $2,500,000 est. value
Purchase, NY

Cleaning and Closed Circuit Television Inspection of Storm Drain Systems
Post-Bid
Bayonne, Fort Lee, Jersey City, Newark, Teterboro, NJ - New Windsor, NY 07608

Catch Basins-Frames, Grates and Curbs
Post-Bid
Pomona, NY 10970

Westside Ballston Lake Sewers - Contract 2
Results
Less than $3,500,000 est. value
Ballston Lake, NY 12019

Green Infrastructure Improvements
Results
Middletown, NY 10940

Storm Materials
Post-Bid
Hannacroix, NY 12087

Belden Center Drainage Improvement Project, Phase 2 - Rhode Island Avenue
Results
Niagara Falls, NY 14305

West Bay Road Storm Sewer Improvements
Post-Bid
Sterling, NY 13156

Woodlawn Park Stormwater Harvesting Project
Results
Albany, NY 12207

Purchase of 14 Curb Inlet Grates
Post-Bid
Yonkers, NY 10701

Garrison Road Storm Sewer Slip-Lining
Term Contract
Results
Queensbury, NY 12804

Street Resiliency Project
Post-Bid
Waterford, NY

Construction of Stormwater Retrofit Project MK-NC-22
Results
Mount Kisco, NY

Allen Hall Storm Sewer
Post-Bid
Buffalo, NY

Last Updated 11/08/2021 08:25 AM
Project Title

Precast Catch Basins, Dry Wells, Frames and Covers

Physical Address View project details and contacts
City, State (County) NY   (Saratoga County)
Category(s) Sewer and Water
Sub-Category(s) Storm/Sewers
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

To secure a bid for Precast Catch Basins, Dry Wells, Frames and Covers. Under this item, the supplier shall furnish 2'6", 3' and 4' (inside Height) precast concrete catch basins with a minimum inside dimension of 2'6" by 2'6". Catch basins shall be as manufactured by the Fort Miller Co., or approved equal, with knockout panels on all four (4) walls. Knockout panel dimensions are as follows: 2'6" unit - 24" x 24" centered on sidewalls; 3' unit - 24" x 30" to inside bottom of catch basin; 4' unit - 24" x 42" to inside bottom of catch basin. All catch basins shall be designed for AASHTO H-20 Loading. Under this item, the supplier shall furnish 1-1/2", 4", 6" high square grade extensions with an outside dimension of 42" x 42" and an inside opening of 30" x 30" for frame and grate. Precast concrete extensions shall be constructed with minimum of 4,000 PSI concrete and shall be adequately reinforced. Grade extensions shall be designed for AASHTO H-20 loading. All risers shall have two (2) lifting hooks. Under this item, the supplier shall furnish 6' and 8' diameter dry well components, as manufactured by the Fort Miller Co., or approved equal. Under this item, the supplier shall furnish heavy duty frame and grate. Campbell Foundry Pattern #2816, or approved equal.

Details

Division 03 - Concrete, Precast Concrete.
Division 33 - Utilities, Storm Drainage Utilities, Storm Utility Drainage Piping, Storm Utility Water Drains, Utility Area Drains, Catchbasins, Storm Drainage Structures.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents