Similar Projects
Cedar Street and Driftwood Street Improvements
Bidding
Royalton, MN

Grading, Aggregate Base, Bituminous Surfacing, Concrete Curb and Gutter, Concrete Walks, Water Main, Sanitary Sewer, and Related Restoration
Bidding
MN

Ground Thawing Services
Term Contract
Post-Bid
Less than $175,000 est. value
Minneapolis, MN

Phase 3A-2 Infrastructure Improvements
Post-Bid
Tracy, MN

20" Forcemain Replacement
Results
Saint Joseph, MN

Meter Station M228A, Interceptor 7015C, and L35 Repair
Renovation, Addition
Results
Brooklyn Park, Maple Grove, MN 55101

Bryant Lane Area Improvements
Bidding
Inver Grove Heights, MN 55076

2021 Infrastructure Improvements
Post-Bid
$1,500,000 to $2,000,000 est. value
MN

Water System Expansion Utility Improvements
Results
Carver, MN 55315

Energy Hills, Woodland Ponds, Wintergreen Area Street Reconstruction
Bidding
Maple Grove, MN

Ductile Iron Pipe
Term Contract
Post-Bid
Minneapolis, MN

Ridgedale Drive Watermain Replacement
Results
Minnetonka, MN 55305

Oyate Place Phase 2 - Street and Utility Improvements
Bidding
$1,309,716 est. value
Welch, MN

Grandview South Area Street and Utility Improvements Improvement
Post-Bid
$9,000,000 to $10,000,000 est. value
Brooklyn Center, MN

Brookdale Park Neighborhood Reconstruction
Results
Less than $5,900,000 est. value
Brooklyn Park, MN 55444

Reported 04/27/2021 12:00 AM
Project Title

AO Smith Btr500 120 Natural Gas Water Heater

Physical Address View project details and contacts
City, State (County) MN   (Ramsey County)
Category(s) Sewer and Water
Sub-Category(s) Water Lines
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

120 Natural Gas Commercial Water Heater, Natural Gas Water Heater shall be A.O. Smith Master-Fit # model # BTR500 120 with a storage capacity of 85 gallons, an input rating of 500,000 BTUs per hour, a recovery rating of 485 gallons per hour (gph) at 100*F rise and a maximum hydrostatic working pressure of 160 PST. Water heater shall be protected against overheating caused by the buildup pf scale, film and other sediment by self-cleaning device, positioned inside the tank so that it directs the flow of inlet water to keep precipitated solids in suspension so that they are removed from the water heater on that or successive draws. Glass lined water heater shall be protected against electrolytic corrosion by multiple factory-installed anode rods. In addition, water heater shall: 1) Be equipped with an integrated control system consisting of a 180*F adjustable thermostat with upper and lower sensing bulbs. 2) Be equipped with intermittent electronic ignition, a manual reset gas shutoff device, a gas pressure regulator, factory installed, CSA Certified and ASME Rated T&P Relief valve and 2 3/4" x 3 3/4" tank inspection port. 3) Be design -certified by UL 4) Meets the thermal efficiency and standby kiss requirements of the U.S Dept of Energy and Current Edition of ASHRAE / IESNA 90.1. 5) Have a 3-year limited warranty against corrosion as outlined in the warranty.

Details

Division 33 - Utilities, Instrumentation and Control for Utilities, Water Utilities, Water Utility Distribution Piping, Water Utility Distribution Equipment, Disinfecting of Water Utility Distribution, Water Utility Storage Tanks.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents