Similar Projects
137th SOW Roof Sustainment Project
Design
Oklahoma City, OK 73179

137th SOW Roof Sustainment Project
Design
Oklahoma City, OK 73179

Sports Complex Roof and HVAC Replacement
Alteration
Bidding
$500,000 est. value
Broken Bow, OK 74728

Bridge Painting - US-270/SH-10
Alteration
Bidding
$400,000 est. value
Tecumseh, OK

TAC Roof Program B9001 - Multiple Award Task Order Contract (MATOC)
Post-Bid
$2,000 to $15,000,000 est. value

TAC Roof Program B9001 - Multiple Award Task Order Contract (MATOC)
Post-Bid
$2,000 to $15,000,000 est. value

Bridge Painting
Alteration
Results

Bridge Painting
Alteration
Results

Painting the Interior and Exterior of 350,000-Gallon Hydro-pillar Style Tower
Alteration
Bidding
$135,000 est. value
Quapaw, OK

Exterior Painting of Various Buildings at Central Maintenance
Post-Bid
Oklahoma City, OK

Window Repair and Replacement and Paint Building 6
Term Contract
Results
El Reno, OK 73036

National Roofing Program Project #6
Term Contract
Post-Bid
$500,000 to $1,000,000 est. value
Phoenix, AZ - Bartlesville, Stillwater, OK

Ottawa County Health Dept Building Roof
Alteration
Results
Miami, OK

Painting Services - Tulsa Region
Alteration
Post-Bid
$175,000 est. value
Oklahoma City, OK 73111

Terminal Building Roof Repairs and Replacement
Alteration
Results
$4,245,176 est. value
OK 73159

Last Updated 04/28/2022 08:25 AM
Project Title

Repair East & West Lean To Roof B187

Physical Address View project details and contacts
City, State (County) Enid, OK 73703   (Garfield County)
Category(s) Single Trades
Sub-Category(s) Painting, Roofing
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The Work of the Project includes the following repairs and upgrades to F187 to improve the sustainability and quality of life for the occupants and incidental related work. Repair the foundation grade beam at the southwest corner of the facility. Replace the entire roof of the facility, including all lean-to areas, the valley gutter, and the rain leaders. Repoint select areas of the exterior CMU wall where necessary. Remove all flaking and loose paint and repaint exterior face of facility. Repair the slope of the earth directly along the western exterior wall. Repair the rain guards along the western exterior wall. Repair exterior window seals and caulking. Repair exterior door seals and sweeps. Repaint exterior doors and frames. Repair exterior doors in the south lean-to. Repair the mezzanine railing to meet OSHA requirements. Update exit signs to comply with current life safety codes. Update the electrical panels. Update lighting in the shop (high bay) area to LED lights. Update lighting in smaller rooms to LED lights.

Details

Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.
Division 09 - Finishes, Painting.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents