Similar Projects
Last Updated | 05/05/2023 05:03 PM |
Project Title | Green Valley Road Water Line Extension |
Physical Address | View project details and contacts |
City, State (County) | Cameron, WV 26033 (Marshall County) |
Category(s) | Heavy and Highway, Sewer and Water |
Sub-Category(s) | Maintenance, Paving/Reconstruction, Site Development, Water Lines |
Contracting Method | Competitive Bids |
Project Status | Contract Award, Construction start expected January 2023 |
Bids Due | View project details and contacts |
Estimated Value | $632,975 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The Project includes the following Work: 1 LS Mobilization/Demobilization; 3,000 LF Restoration of Disturbed Area; 1 LS Erosion and Sediment Control Measures; 300 LF WVDOH Type "A-2" Trench Repair with Crusher Run Stone, Concrete, Rebar, Tack Coat, and Hot Mixed Asphalt; 170 LF WVDOH Type "B" Trench Repair; 1,000 LF WVDOH Type "C" Trench Repair; 11,400 SF Full Width Roadway Crushed Stone Repair; 70 TN 2" Milling and Overlay of Bituminous Concrete Pavement (WVDOH Marshall Type (1) Wearing Course); 65 LF Concrete Paving and Sidewalks; 200 LF Horizontal Directionally Drilled 8" DR11 (Pressure Rating 200 PSI) Ductile Iron Pipe Size High Density Polyethylene Pipe Water Line; 700 LF Horizontal Directionally Drilled 6" DR11 (Pressure Rating 200 PSI) Ductile Iron Pipe Size High Density Polyethylene Pipe Water Line; 530 LF Horizontal Directionally Drilled 2" DR11 (Pressure Rating 200 PSI) Ductile Iron Pipe Size High Density Polyethylene Pipe Water Line; 300 LF Open Cut 3/4 " Polyethylene SDR 9 Service Tubing; 300 LF Bored and Jacked 3/4 " Polyethylene SDR 9 Service Tubing with 2" PVC Casing; 80 LF 2" PVC SDR 13.5 (Pressure Rating 315 PSI) Water Line; 1,600 LF 8" AWWA C900 DR18 (Pressure Class 235 PSI) PVC Water Line; 2,200 LF 6" AWWA C900 DR18 (Pressure Class 235 PSI) PVC Water Line; 60 LF 8" (Thickness Class 52) Ductile Iron Pipe without Polyethylene Encasement; 100 LF 6" (Thickness Class 52) Ductile Iron Pipe without Polyethylene Encasement; 1 EA Hot Tap Tie-In New 8" Water Line to Existing 8" Water Line Including One (1) Gate Valve; 2 EA 2" Post Flushing Hydrant Assembly; 1 EA 3/4" Air Release Valve; 10 EA Reinforced Concrete Anchors; 20 EA 3/4" High Pressure Single Meter Setting with New Meters; 3 EA Reconnect Existing Customers to New 8" Line with New Meters; 1 EA 8" Gate Valve; 4 EA 6" Gate Valve; 1 EA 2" Gate Valve; 3 EA Fire Hydrant Assembly. |
||||||
Details |
|
||||||
Bidder's List | View project details and contacts | ||||||
Prospective Bidders | View project details and contacts | ||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |