Last Updated 07/17/2020 05:25 AM
Project Title

Guardrail Rebuilding - Gr Fy2021/2022 (Ding N Dent)

Physical Address View project details and contacts
City, State (County) (Coshocton, Fairfield, Guernsey, Knox, Licking, Muskingum, Perry Counties)
Category(s) Heavy and Highway
Sub-Category(s) Highway Signs/Guardrails/Barriers
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

For Improving Various Sections In Coshocton, Fairfield, Guernsey, Knox, Licking, Muskingum & Perry Counties, Of Ohio, In Accordance With Plans And Specifications By Repairing Or Replacing Damaged Guardrail And Their Assemblies To Maintain a Fully Functional Barrier System. Section Roadway 0001 Line Item Code Quantity Unit Item Description Wt Alt 0001 202e38000 20,000.000 Ft Guardrail Removed (Wt: Nr) Nr 0002 202e38500 300.000 Ft Bridge Railing Removed (Wt: Nr) Nr 0003 202e42000 20.000 Each Anchor Assembly Removed, Type a (Wt: Nr) Nr 0004 202e42010 100.000 Each Anchor Assembly Removed, Type e (Wt: Nr) Nr 0005 202e42040 20.000 Each Anchor Assembly Removed, Type t (Wt: Nr) Nr 0006 202e42050 15.000 Each Anchor Assembly Removed, Type b (Wt: Nr) Nr 0007 202e47000 10.000 Each Bridge Terminal Assembly Removed (Wt: Nr) Nr 0008 202e47800 5.000 Each Impact Attenuator Removed (Wt: Nr) Nr 0009 203e20000 15.000 Cy Embankment (Wt: 36) 36 0010 606e13000 15,000.000 Ft Guardrail, Type 5 (Wt: 36) 36 0011 606e13050 200.000 Ft Guardrail, Type 5a (Wt: 36) 36 0012 606e15050 2,000.000 Ft Guardrail, Type Mgs (Wt: 36) 36 0013 606e15500 500.000 Ft Guardrail, Barrier Design, Type 5 (Wt: 36) 36 0014 606e16001 15,000.000 Ft Guardrail Rebuilt, As Per Plan (Wt: 36) 36 0015 606e16051 1,500.000 Ft Guardrail Rebuilt, Type Mgs, As Per Plan (Wt: 36) 36 0016 606e17360 25.000 Ft Guardrail, Type Mgs, Long-Span (Wt: 36) 36 0017 606e17700 400.000 Each Replace Existing Guardrail Blockout (Wt: 36) 36 0018 606e17750 50.000 Each Replace Existing Guardrail Blockout, Type Mgs (Wt: 36) 36 0019 606e17901 400.000 Each Guardrail Post, As Per Plan (Wt: 36) 36 0020 606e18500 150.000 Each Guardrail Post, 9 Feet (Wt: 36) 36 0021 606e18501 150.000 Each Guardrail Post, 9 Feet, As Per Plan (Wt: 36) 36 0022 606e25000 15.000 Each Anchor Assembly, Type a (Wt: 36) 36 0023 606e25550 1.000 Each Anchor Assembly, Mgs Type a (Wt: 36) 36 0024 606e26000 10.000 Each Anchor Assembly, Type b (Wt: 36) 36 0025 606e26050 1.000 Each Anchor Assembly, Mgs Type b (Wt: 36) 36 0026 606e26100 75.000 Each Anchor Assembly, Type e (Wt: 36) 36 0027 606e26150 25.000 Each Anchor Assembly, Mgs Type e (Nchrp 350 Or Mash 2016) (Wt: 36) 36 0028 606e26500 25.000 Each Anchor Assembly, Type t (Wt: 36) 36 0029 606e26550 6.000 Each Anchor Assembly, Mgs Type t (Wt: 36) 36 0030 606e27801 20.000 Each Anchor Assembly Rebuilt, Type a, As Per Plan (Wt: 36) 36 0031 606e27841 20.000 Each Anchor Assembly Rebuilt, Type b, As Per Plan (12.5 Ft. Guardrail, 12.5 Ft. Srt-1 Anc/Guardrail Or 12.5 Ft. Srt-2/Guardrail) (Wt: 36) 36 0032 606e27841 10.000 Each Anchor Assembly Rebuilt, Type b, As Per Plan (Buffer/Rolled Terminal) (Wt: 36) 36 0033 606e27841 4.000 Each Anchor Assembly Rebuilt, Type b, As Per Plan (Cable Assembly) (Wt: 36) 36 0034 606e27841 20.000 Each Anchor Assembly Rebuilt, Type b, As Per Plan (Wood Blocks) (Wt: 36) 36 0035 606e27841 25.000 Each Anchor Assembly Rebuilt, Type b, As Per Plan (Wood Post, 45 Inches Or Wood Post, 72 Inches) (Wt: 36) 36 0036 606e27851 12.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Cable Anchor Bracket) (Wt: 36) 36 0037 606e27851 11.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Cable Assembly) (Wt: 36) 36 0038 606e27851 16.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Deep Beam Guardrail 12 Gauge - 12.5` Or Deep Beam Guardrail 12 Gauge-12.5` End Panel) (Wt: 36) 36 0039 606e27851 60.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Deep Beam Guardrail 12 Gauge - 25` Or Deep Beam Guardrail 12 Gauge-25` End Panel) (Wt: 36) 36 0040 606e27851 10.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Guardrail Extruder) (Wt: 36) 36 0041 606e27851 15.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Hba Post #1-#4 Bottom) (Wt: 36) 36 0042 606e27851 30.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Hba Post #1-#4 Top) (Wt: 36) 36 0043 606e27851 13.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Post Syt #2-#8) (Wt: 36) 36 0044 606e27851 4.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Steel Foundation Tube) (Wt: 36) 36 0045 606e27851 4.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Strut) (Wt: 36) 36 0046 606e27851 35.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Wood Blocks) (Wt: 36) 36 0047 606e27851 50.000 Each Anchor Assembly Rebuilt, Type e, As Per Plan (Wood Post, 45" Or 72") (Wt: 36) 36 0048 606e27900 20.000 Each Anchor Assembly Rebuilt, Type t (Wt: 36) 36 0049 606e27910 4.000 Each Anchor Assembly Rebuilt, Mgs Type t (Wt: 36) 36 0050 606e32160 2.000 Each Bridge Terminal Assembly, Type Tst (Wt: 36) 36 0051 606e32171 1.000 Each Bridge Terminal Assembly Rebuilt, Type Tst, As Per Plan (12.5 Ft Single w-Beam Rail Element) (Wt: 36) 36 0052 606e32171 1.000 Each Bridge Terminal Assembly Rebuilt, Type Tst, As Per Plan (Thrie-Beam Element, Transition Section Or Terminal Connector) (Wt: 36) 36 0053 606e32171 1.000 Each Bridge Terminal Assembly Rebuilt, Type Tst, As Per Plan (Wood Or Steel Post) (Wt: 36) 36 0054 606e35000 10.000 Each Bridge Terminal Assembly, Type 1 (Wt: 36) 36 0055 606e35002 3.000 Each Mgs Bridge Terminal Assembly, Type 1 (Wt: 36) 36 0056 606e35011 1.000 Each Bridge Terminal Assembly Rebuilt, Type 1, As Per Plan (12.5 Ft Rail Element) (Wt: 36) 36 0057 606e35011 10.000 Each Bridge Terminal Assembly Rebuilt, Type 1, As Per Plan (Thrie Beam Rail Element, Transition Section Or Terminal Connector) (Wt: 36) 36 0058 606e35011 10.000 Each Bridge Terminal Assembly Rebuilt, Type 1, As Per Plan (Wood Post Or Steel Post) (Wt: 36) 36 0059 606e35013 4.000 Each Mgs Bridge Terminal Assembly Rebuilt, Type 1, As Per Plan (Thrie Beam Rail Element, Transition Section Or Terminal Connector) (Wt: 36)36 0060 606e35013 2.000 Each Mgs Bridge Terminal Assembly Rebuilt, Type 1, As Per Plan (12.5 Ft Rail Element) (Wt: 36) 36 0061 606e35013 5.000 Each Mgs Bridge Terminal Assembly Rebuilt, Type 1, As Per Plan (Wood Post Or Steel Post) (Wt: 36) 36 0062 606e35100 4.000 Each Bridge Terminal Assembly, Type 2 (Wt: 36) 36 0063 606e35102 2.000 Each Mgs Bridge Terminal Assembly, Type 2 (Wt: 36) 36 0064 606e35140 5.000 Each Bridge Terminal Assembly, Type 4 (Wt: 36) 36 0065 606e35151 1.000 Each Bridge Terminal Assembly Rebuilt, Type 4, As Per Plan (12.5 Ft Rail Element) (Wt: 36) 36 0066 606e35151 30.000 Each Bridge Terminal Assembly Rebuilt, Type 4, As Per Plan (Wood Post Or Steel Post) (Wt: 36) 36 0067 606e39001 1.000 Each 36" Concrete Anchor Removed And Replaced, As Per Plan (Wt: 38) 38 0068 606e50000 300.000 Ft Special - Reshaping Berm (Wt: 06) 06 0069 606e60002 2.000 Each Impact Attenuator, Type 1 (Unidirectional) (Wt: 36) 36 0070 606e60012 2.000 Each Impact Attenuator, Type 1 (Bidirectional) (Wt: 36) 36 0071 606e60022 1.000 Each Impact Attenuator, Type 2 (Unidirectional) (Wt: 36) 36 0072 606e60028 1.000 Each Impact Attenuator, Type 2 (Bidirectional) (Various Speed And Width) (Wt: 36) 36 0073 606e61000 4.000 Each Impact Attenuator, Misc.: Rebuilt, Type 1 (1/4" x 18" x 24" Soil Plate) (Wt: 36) 36 0074 606e61000 15.000 Each Impact Attenuator, Misc.: Rebuilt, Type 1 (3-6" Wood Post #1, 2, 3, 4, 5, 6 Cat) (Wt: 36) 36 0075 606e61000 2.000 Each Impact Attenuator, Misc.: Rebuilt, Type 1 (4-6" Foundation Tube) (Wt: 36)36 0076 606e61000 2.000 Each Impact Attenuator, Misc.: Rebuilt, Type 1 (All Components Post #1 To Post #4, Excluding Posts, Wood Blocks, Foundation Tubes And Soil Plates) (Wt: 36) 36 0077 606e61000 3.000 Each Impact Attenuator, Misc.: Rebuilt, Type 1 (All Components Post #4 To Post #6, Excluding Posts, Wood Blocks, Foundation Tubes And Soil Plates) (Wt: 36) 36 0078 606e61000 20.000 Each Impact Attenuator, Misc.: Rebuilt, Type 1 (Wood Block 1`-2", Post #1, 2, 3, 4, 5, 6 Cat) (Wt: 36) 36 0079 606e61000 1.000 Each Impact Attenuator, Misc.: Rebuilt, Type 2 (Belt Nose Assembly) (Wt: 36) 36 0080 606e61000 4.000 Each Impact Attenuator, Misc.: Rebuilt, Type 2 (Cartridge Type i) (Wt: 36) 36 0081 606e61000 5.000 Each Impact Attenuator, Misc.: Rebuilt, Type 2 (Cartridge Type Ii) (Wt: 36) 36 0082 606e61000 6.000 Each Impact Attenuator, Misc.: Rebuilt, Type 2 (Quad Beam Fender Panel) (Wt: 36) 36 0083 606e98000 200.000 Ft Guardrail, Misc.: Replacement Cable (Wt: 36) 36 0084 606e98000 150.000 Ft Guardrail, Misc.: Tubular Backup (Wt: 36) 36 0085 606e98100 50.000 Each Guardrail, Misc.: 25 Ft. Rail Element (Type a Anchor) (Wt: 36) 36 0086 606e98100 1.000 Each Guardrail, Misc.: Anchor Assembly Rebuilt, Type a, Barrier Design (Wt: 36) 36 0087 606e98100 10.000 Each Guardrail, Misc.: Anchor Post (Wt: 36) 36 0088 606e98100 60.000 Each Guardrail, Misc.: Anchor Post Reset (Wt: 36) 36 0089 606e98100 4.000 Each Guardrail, Misc.: Anchor Trigger Post (Wt: 36) 36 0090 606e98100 213.000 Each Guardrail, Misc.: Annual Cable Tensioning (First Year) (Wt: 36) 36 0091 606e98100 213.000 Each Guardrail, Misc.: Annual Cable Tensioning (Second Year) (Wt: 36) 36 0092 606e98100 5.000 Each Guardrail, Misc.: Cable Splice (Wt: 36) 36 0093 606e98100 5.000 Each Guardrail, Misc.: Concrete Anchor Foundation Anchor Post Base (Wt: 36) 36 0094 606e98100 75.000 Each Guardrail, Misc.: Concrete Line Post Foundation With Sleeve (Wt: 36) 36 0095 606e98100 900.000 Each Guardrail, Misc.: Line Post (Wt: 36) 36 0096 606e98100 150.000 Each Guardrail, Misc.: Post Reflector (Wt: 36) 36 0097 606e98100 100.000 Each Guardrail, Misc.: Readjust Cable Tension (Repair) (Wt: 36) 36 0098 606e98100 80.000 Each Guardrail, Misc.: Urgent Repair (Wt: 36) 36 Section Erosion Control 0002 Line Item Code Quantity Unit Item Description Wt Alt 0099 832e30000 1,000.000 Each Erosion Control (Wt: 08) 08 Section Traffic Control 0003 Line Item Code Quantity Unit Item Description Wt Alt 0100 626e00110 15.000 Each Barrier Reflector, Type 2 (1 Way) (Wt: Nr) Nr 0101 626e00110 15.000 Each Barrier Reflector, Type 2 (Bidirectional) (Wt: Nr) Nr Section Maintenance Of Traffic 0004 Line Item Code Quantity Unit Item Description Wt Alt 0102 614e11110 100.000 Hour Law Enforcement Officer With Patrol Car For Assistance (Wt: 39) 39 0103 614e13600 400.000 Each Maintenance Of Traffic, One Lane Closure On a Two Lane Highway (Wt: 39) 39 0104 614e13700 20.000 Each Maintenance Of Traffic, One Lane Closure On a Four Lane Undivided Highway (Wt: 39) 39 0105 614e13800 60.000 Each Maintenance Of Traffic, One Lane Closure On a 4 Lane Or Greater Divided Highway (Wt: 39) 39 0106 614e13900 500.000 Each Maintenance Of Traffic For Shoulder Closure (Wt: 39) 39 Section Miscellaneous Structure 0005 Line Item Code Quantity Unit Item Description Wt Alt 0107 517e70000 25.000 Ft Railing (Twin Steel Tube) (Wt: 36) 36 0108 517e72300 25.000 Ft Railing (Deep Beam Rail With Steel Tubular Backup And Type 2 Steel Posts And Anchor Bolts) (Wt: 36) 36 0109 517e72750 25.000 Ft Railing (Thrie Beam Retrofit) (Wt: 36) 36 Section Incidentals 0006 Line Item Code Quantity Unit Item Description Wt Alt 0110 103e05000 1.000 Ls Premium For Contract Performance Bond And For Payment Bond (Wt: Nr) Nr 0111 624e10000 1.000 Ls Mobilization (Wt: Nr) Nr

Details

Division 34 - Transportation, Roadway Construction, Vehicle Barriers, Vehicle Guide Rails.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents