Similar Projects
Fire Alarm System Replacement for Dorms 1, 2, 3 and 4
Alteration
Results
Raleigh, NC 27604

Fire Sprinkler Systems Installation and Repair Service
Term Contract
Post-Bid
NC

Fire Alarm Systems Installation and Repair - Mircom Systems Service
Term Contract
Post-Bid
NC

Fire Alarm Systems Installation and Repair - Simplex Grinnell Systems Service
Term Contract
Post-Bid
NC

Fire Alarm Systems Installation and Repair - Siemens System Service
Term Contract
Post-Bid
NC

Fire Alarm Systems Installation and Repair
Term Contract
Post-Bid
NC

Fire Sprinkler System Inspections Service - JOC/SA
Term Contract
Post-Bid
NC

Fire Alarm Monitoring Service
Term Contract
Post-Bid
NC

Fire Extinguisher Inspection and Repair Service
Term Contract
Post-Bid
NC

Fire Extinguisher Annual Maintenance
Term Contract
Post-Bid
Raleigh, NC

Fire Extinguisher Maintenance
Term Contract
Post-Bid
Raleigh, NC 27601

Fire Extinguishers - Services, Accessories, Purchases
Term Contract
Post-Bid
Raleigh, NC 27601

RFQ Contractor - Bowen Residence Hall Fire Alarm System Replacement
Renovation
Post-Bid
$800,000 CJ est. value
Raleigh, NC 27607

Witherspoon Student Center Fire Alarm System Replacement
LEED Certification, Renovation
Post-Bid
$500,000 CJ est. value
Raleigh, NC 27606

Fireproofing Security and Access Control
Renovation
Post-Bid
$500,000 CJ est. value
Cary, NC 27513

Reported 09/14/2023 12:00 AM
Project Title

Poe Hall - Fire Protection System Improvements

Physical Address View project details and contacts
City, State (County) Raleigh, NC 27607   (Wake County)
Category(s) Single Trades
Sub-Category(s) Fire Protection
Contracting Method Competitive Bids
Project Status Bidding,
Bids Due View project details and contacts
Estimated Value $3,500,000 [brand] Estimate
Plans Available from Consultant
Owner View project details and contacts
Architect View project details and contacts
Description

NCSU has put the project on hold. No new bid date has been announced. PROJECT DESCRIPTION A. The project entails standpipe upgrades at Poe Hall. 1. Provide new fire line into building, interconnecting with existing combined fire/domestic service with back flow prevention. 2. Separation of domestic service with back flow prevention. 3. Selective demolition of the existing mechanical room which includes removal of the existing chiller and associated pumps and electrical services. 4. Relocation of controls air compressor. 5. Creation of a new fire pump room. 6. Installation of a new fire pump, jockey pump, associated controllers and piping. 7. Removal and replacement of all existing standpipes. 8. Replacement of the existing fire alarm control panel and integration of new and existing devices. Preferred manufacturers for mechanical door hardware are listed in the 012300 - Alternate section of the specifications. The state reserves the unqualified right to reject any and all proposals An open public meeting will be held at 2:30 pm on August 23, 2023, in Conference Room 301 of Administrative Services III Building at 2601 Wolf Village Way, Raleigh, NC 27695.

Details

Division 21 - Fire Suppression.
Division 28 - Electronic Safety and Security, Fire Detection and Alarm.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents