Similar Projects
HVAC and Mechanical Products
Term Contract
Post-Bid

HVAC Repair and Replacement
Post-Bid
Fort Wayne, IN 46805

Fort Wayne Campus - Neff Hall HVAC Unit Ac-1 Replacement -2021
Alteration
Results
Fort Wayne, IN

2022 Snider and South Side High School HVAC
Alteration
Results
Fort Wayne, IN 46815

Pre-Conditioned Air Units and 2 Ground Power Units
Post-Bid
Fort Wayne, IN

ESSER 2022 Ventilation at South Side High School
Alteration
Results
$975,000 est. value
Fort Wayne, IN 46806

HVAC and Mechanical Products and Solutions
Term Contract
Post-Bid

ESSER 2022 Ventilation at Kekionga Middle School
Alteration
Results
$510,000 est. value
Fort Wayne, IN 46809

Eskenazi Health-SEMHC-Two AHU`s and Controls Replacement CMc Proposals
Renovation, Alteration
Post-Bid

ESSER 2022 Elementary Ventilation (Adams, Forest Park and Study)
Alteration
Results
$707,000 est. value
Fort Wayne, IN 46803

Guaranteed Energy Savings Project HVAC Improvements
Alteration
Post-Bid
Fort Wayne, IN

FWCS ESSER HVAC Improvements at the Anthis Automotive Center
Alteration
Results
Fort Wayne, IN 46802

2021 Ventilation (ESSER) Franke Park and Towles Intermediate Schools
Alteration
Post-Bid
Fort Wayne, IN

Coliseum Campus Building 2 Rooftop Unit Replacement
Alteration
Results
$779,084 est. value
Fort Wayne, IN 46805

Chiller Plant Cooling Towers Phase II
Alteration
Post-Bid
Fort Wayne, IN 46805

Last Updated 07/15/2022 12:29 AM
Project Title

Plant HVAC Improvement - Phase II

Physical Address View project details and contacts
City, State (County) Fort Wayne, IN 46805   (Allen County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $600,000 [brand] Estimate
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The funding source for this project is WATER SRF The Contractor shall furnish all labor, insurance, equipment, materials and power for the complete performance of the following project, Plant HVAC Improvement - Phase II as follows: The Work generally includes the removal of two existing windows and replacement with new Aluminum Framed storefronts, the removal of existing window air conditioning units (11 total), and the installation of new air condition systems consisting of Variable Refrigerant Flow (VRF) HVAC systems, energy recovery ventilators, and all associated piping, ductwork, controls, electrical power, wiring, and other appurtenances. all in accordance with the Bidding Documents as prepared by City Utilities Engineering. No Bid will be accepted from, or contract awarded to any person, firm, or corporation that is in arrears to the City of Fort Wayne, Indiana, upon any debt or contract, or, who has failed to execute, in whole or in part in a satisfactory manner, any contract with the City; or, who is a defaulter as to surety or otherwise, upon any obligation to the City, or is engaged in litigation with the City.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents