Similar Projects
Replacement of the Sand Hill Water Storage Tank
Design
Less than $2,070,000 est. value
Cottekill, NY

Water System Improvements
Bidding
Hancock, NY

Tank Lining
Post-Bid
Buffalo, NY 14202

World-Wide Water Storage Tank Remediation
Term Contract
Post-Bid

Gallon Water Tank Rehabilitation
Results
South Glens Falls, NY 12803

Salt, Brine, and Anti-Icing or De-Icing Agents, and Brine Production and Storage Systems
Results

FAGE USA New Water Storage Tank Building
New Construction, Renovation
Construction
Johnstown, NY 12095

Furnish and Install a Submersible Water Storage Tank Mixer and Cathodic Protection System
Post-Bid
Petersburg, NY 12138

Rehabilitation of 100,000 Gallon Elevated Water Storage Tank
Results
Ballston Spa, NY 12020

Lake Water System Improvements Project - Contract No. 3 - Spray Aeration Treatment
Post-Bid
Less than $225,000 est. value
Round Lake, NY 12151

Dover Ridge Water Supply – Water System Improvements
Results
Less than $400,000 est. value
Poughquag, NY 12570

Water Storage Tank Improvement
Post-Bid
Wilson, NY 14172

BPS-2 Water Storage Tank THM Removal System
Results
Watertown, NY 13601

Fluoride System Upgrade at Reeves Newsom Water Service Station
Post-Bid
Scarsdale, NY 10583

East Water Tank Replacement at Lake Taghkanic State Park
Results
Less than $1,028,000 est. value
Ancram, NY 12502

Last Updated 08/20/2020 04:47 PM
Project Title

Rehabilitation of the Winged Food Elevated Storage Tank

Physical Address View project details and contacts
City, State (County) Mamaroneck, NY 10543   (Westchester County)
Category(s) Sewer and Water
Sub-Category(s) Storage/Water Tanks
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Rehabilitation of a 750,000 Gallon Elevated Storage Tank at the Westchester Joint Water Works Winged Foot site. The project includes: Blast and paint interior water cavity and exterior surfaces, Fu containment in accordance with CAMP/SSPC Guide 2A requirements, Remove and replace existing tank vent Remove and replace existing interior and water cavity ladders and safety clmb (alternate). Provide new tank roof railing. Remove, replace, and relocate existing tank lighting and conduit Installation of new Coax Cable Shroud. Blast and paint exterior foundation. Access hatch modifications, Remove and replace existing tank beacon lighting, Installation of new tank mounting brackets. Disinfection and water quality testing. Project closeout submittals.

Details

Division 02 - Existing Conditions, Subsurface Investigation.
Division 03 - Concrete, Concrete Reinforcing, Cast-in-Place Concrete.
Division 05 - Metals, Structural Metal Framing, Metal Decking.
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Facility Fuel Piping, Facility Fuel-Storage Tanks.
Division 31 - Earthwork, Clearing and Grubbing, Grading.
Division 32 - Exterior Improvements, Fences and Gates.
Division 33 - Utilities, Storm Drainage Utilities.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents