Similar Projects
Boilers Replacement Building C And D
Bidding
Marietta, GA 30060

LK Moss HVAC Replacement
Bidding
Buena Vista, GA 31803

HVAC Coil Cleaning
Post-Bid
Atlanta, GA

HVAC Maintenance and Repair Services
Post-Bid
Atlanta, GA 30303

HVAC Service to Include Repair and Maintenance
Term Contract
Results
Powder Springs, GA 30127

Shallowford Falls Elementary School Kitchen Hood and HVAC Renovations
Results
Less than $303,000 est. value
Marietta, GA 30062

Kitchen HVAC Renovations
Post-Bid
Sandy Plains, GA 30075

Lassiter/Sprayberry HS HVAC Improvement Chiller Replacement
Results
Less than $1,479,935 est. value
Marietta, GA 30060

Hydraulic Cylinder, Components, Pump Repairs, Hose Fabrication
Post-Bid
Atlanta, GA

Addison Elementary Energy Recovery Unit
Addition
Results
Less than $36,388 est. value
Kennesaw, GA 30152

HVAC Filtration Systems Upgrades
Post-Bid
Austell, GA 30106

Addison Elementary VRF Heat Recovery System
Results
Less than $33,370 est. value
Kennesaw, GA 30152

HVAC and Mechanical Products
Term Contract
Post-Bid

Addison Elementary Rooftop Units
Results
Less than $81,715 est. value
Kennesaw, GA 30152

Chiller and Cooling Tower Maintenance Service
Term Contract
Post-Bid
Marietta, GA 30060

Last Updated 03/29/2021 08:35 AM
Project Title

30 Ton Rooftop Unit Timber Ridge ES

Physical Address View project details and contacts
City, State (County) Marietta, GA 30068   (Cobb County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Unit must include the following: 1. 3-Phase power protection. 2. Hail guards on all condenser/outdoor coils. 3. Hinged doors with tool-less entry. 4. Minimum Energy Efficiency Ratio shall be 12. 5. Stainless - steel or composite condensate pans, sloped to comply with ASHRAE 62. 6. Coils shall be aluminum fin, mechanically bonded to seamless copper tubing. Copper evaporator and condenser coils are preferred. Total aluminum condenser coils will be accepted with the prior approval of the CCSD Maintenance Department. 7. Compressors shall be hermetic type equipped with low, and high- pressure cutouts, motor overload protection, crankcase heater, and compressor time delay nonrecycling relay. 8. Stainless steel gas heat exchangers. Controls shall include high limit, intermittent spark ignition, pilot flame sensor, main gas valve and redundant gas valve to achieve 100% pilot shut-off. 9. Hot gas re-heat for dehumidification to be controlled by the building automation system. Unit shall provide neutral supply air between 68 and 75 degrees. 10. Evaporator fans shall be a forward curved or vane axial centrifugal with direct drive motors on units 5 ton and smaller and adjustable V-belt drive on units larger than 5 tons. Motors shall have thermal overload protection. Ductwork shall be engineered with static pressure no greater than 1.0. An automatic belt tensioner may be allowed (ONLY) if approved by the Cobb County School District Maintenance Department and the Mechanical Engineer. If a higher efficiency RTU with a direct drive motor will provide the engineers designed static pressure, submit the higher efficient unit.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents