Similar Projects
Last Updated | 03/29/2023 12:05 PM |
Project Title | Tinker Operations Building |
Physical Address | View project details and contacts |
City, State (County) | Tribbey, OK 74878 (Pottawatomie County) |
Category(s) | Government/Public, Heavy and Highway, Sewer and Water |
Sub-Category(s) | Misc. Buildings, Site Development, Water Lines |
Contracting Method | Bids by Invitation |
Project Status | Bidding, Construction start expected May 2023 |
Bids Due | View project details and contacts |
Estimated Value | $4,332,340 [brand] Estimate |
Plans Available from | Owner's Representative |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Bid security percent:5% Comply with requirements in Section 312000 "Earth Moving" for excavating, trenching, and backfilling. 3.3 INSTALLATION OF PIPING A. Drawing plans, schematics, and diagrams indicate general location and arrangement of domestic water piping. Indicated locations and arrangements are used to size pipe and calculate friction loss, expansion, and other design considerations. Install piping as indicated unless deviations to layout are approved on coordination drawings. B. Install copper tubing under building slab according to CDA's "Copper Tube Handbook." C. Install valves according to the following: 1. Section 220523.12 "Ball Valves for Plumbing Piping." 2. Section 220523.14 "Check Valves for Plumbing Piping." D. Install domestic water piping level without pitch and plumb. E. Rough-in domestic water piping for water-meter installation according to utility company's requirements. F. Install piping concealed from view and protected from physical contact by building occupants unless otherwise indicated and except in equipment rooms and service areas. G. Install piping indicated to be exposed and piping in equipment rooms and service areas at right angles or parallel to building walls. Diagonal runs are prohibited unless specifically indicated otherwise. H. Install piping above accessible ceilings to allow sufficient space for ceiling panel removal, and coordinate with other services occupying that space. I. Install piping to permit valve servicing. J. Install nipples, unions, special fittings, and valves with pressure ratings the same as or higher than the system pressure rating used in applications below unless otherwise indicated. K. Install piping free of sags and bends. L. Install fittings for changes in direction and branch connections. M. Install unions in copper tubing at final connection to each piece of equipment, machine, and specialty. N. Install thermometers on inlet and outlet piping from each water heater. Comply with requirements for thermometers in Section 220519 "Meters and Gages for Plumbing Piping." O. Install sleeves for piping penetrations of walls, ceilings, and floors. Comply with requirements for sleeves specified in Section 220517 "Sleeves and Sleeve Seals for Plumbing Piping." P. Install sleeve seals for piping penetrations of concrete walls and slabs. Comply with requirements for sleeve seals specified in Section 220517 "Sleeves and Sleeve Seals for Plumbing Piping." Q. Install escutcheons for piping penetrations of walls, ceilings, and floors. Comply with requirements for escutcheons specified in Section 220518 "Escutcheons for Plumbing Piping. |
||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |