Similar Projects
Fuel Tank Inspection for USCG Base Elizabeth City, NC
Bidding
Elizabeth City, NC 27909

Diesel Fuel Ast Replacement
Bidding
Fayetteville, NC

Underground Storage Tank Removal
Post-Bid
Cary, NC

Replace Natural Gas Piping (House Piping)
Post-Bid
Weldon, NC 27890

Main Campus Steam Plant - Fuel Oil Containment Facilities Replacement
Results
Less than $2,227,900 est. value
Greenville, NC 27858

Residential Gas Meters
Results
Rocky Mount, NC

Demolition Services for Harnett County Public Building/Facilities Management
Demolition
Post-Bid
Olivia, NC 27332

Hypochlorite Tank #1 Replacement
Results
Less than $520,000 est. value
Kannapolis, NC

Former Police HQ Building - Underground Storage Tank Closure
Post-Bid
Raleigh, NC 27601

Fuel Farm Expansion Phase III
Results
Charlotte, NC

Petroleum Tank Installation, Operations and Maintenance Services
Term Contract
Post-Bid
Charlotte, NC 28206

Gas Leak Detection and Atmospheric Corrosion Survey Services
Term Contract
Results
Greenville, NC 27834

Fuel Storage Tanks
Term Contract
Post-Bid
Raleigh, NC 27699

Boat Refueling System Repairs for the U.S. Coast Guard (USCG) Station Hatteras Inlet
Results
Hatteras, NC 27943

Liquefied Petroleum Gas & Tank Monitoring Services
Post-Bid
Jacksonville, NC 28542

Last Updated 03/24/2021 01:27 PM
Project Title

Nano Plant Chemical Line Replacment-Fy21-02

Physical Address View project details and contacts
City, State (County) Jacksonville, NC   (Onslow County)
Category(s) Sewer and Water
Sub-Category(s) Fuel/Chemical Tanks and Lines
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The project consists of the following: A. Base Bid (Chemical Piping Improvements) 1. Furnish and install all labor and materials necessary for dedicated chemical feed piping for the sodium hypochlorite, caustic, and zinc orthophosphate systems as well as relocation of existing feedwater piping and fittings within process trench to locate sulfuric acid injection downstream of the bypass flow control valve. Construct approximately 257 LF of ½” ZN3(PO4)2 piping, 274 LF of ¾” NaOH piping, 258 LF of ¾” NaOCI piping, valves, appurtenances, leak inspection port, penetrations, pipe supports, chemical piping relocation, injection ports, insulation, heat tracing, thermostats, associated electrical conduits, boxes, miscellaneous piping, supports, and accessory items necessary to provide a complete operating system. 2. The Contractor shall hire Lord and Company, Inc. to perform the programming, controls, and integration for the proposed changes. The contact at Lord and Company is Derek Mathews and he may be reached at (803) 802-0060 or at e-mail address of dmathews@lordandcompany.com. This work includes recalibration of scale inhibitor, zinc orthophosphate, sodium hypochlorite, caustic and scale inhibitor injection systems and modifications to the HMI screens, as necessary. Currently, there are sufficient spare Input/Output to accommodate new signals, however, it is the responsibility of the Contractor to investigate the main SCADA panel to ensure the spare I/O is available at the beginning of the project.

Details

Division 02 - Existing Conditions, Subsurface Investigation.
Division 03 - Concrete, Concrete Reinforcing, Cast-in-Place Concrete.
Division 05 - Metals, Structural Metal Framing, Metal Decking.
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Facility Fuel Piping, Facility Fuel-Storage Tanks.
Division 31 - Earthwork, Clearing and Grubbing, Grading.
Division 32 - Exterior Improvements, Fences and Gates.
Division 33 - Utilities, Storm Drainage Utilities.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents