Similar Projects
Last Updated | 06/28/2023 05:02 PM |
Project Title | Access Door Control Release Project |
Physical Address | View project details and contacts |
City, State (County) | Newark, NJ 07103 (Essex County) |
Category(s) | Single Trades |
Sub-Category(s) | Windows/Doors |
Contracting Method | Competitive Bids |
Project Status | Sub-Bidding, Construction start expected July 2023 |
Bids Due | View project details and contacts |
Estimated Value | $100,000 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Access Door Control Release Project. door release system access control system The entire work of the Project shall be completed in 60 Calendar Days All questions must be submitted in writing to the Office of Purchasing via fax to 973-621-5109, no later than 4:30 PM end of business day, eight (8) business days prior to deadline for bid submission date as stated above. *The list of planholders and/or interested bidders is not being tracked by the stakeholders involved with this project. If you are an interested contractor and wish to be listed as a bidder, please notify our editorial staff at addtobidlist@constructconnect.com 1. Door Release as soon as a fire is detected, including software, equipment, programming, installing, providing power supply including software, equipment, programming, installing, providing power supply, and 2. Access Control to enter an exit a room, including software, equipment, programming, installing, providing power supply, card reader, cards. The contractor shall provide the following for the two parts of this contract: DOOR RELEASE SYSTEM: Addressable Relays above each door to release the access control doors in the lower school area (15 Units) Provide power to the door locks. Connect to the fire alarm relays. Install raceway, wiring, boxes and all necessary equipment for the installation of the fire alarm devices. Program the installed fire alarm devices into the existing 4100ES fire panel. Test the installed fire alarm devices. Perform an 10% Test of the non-effected fire alarm devices Provide re-acceptance testing documentation upon completion. Provide DCA Fire alarm submittals, fire alarm stamped drawings and permits. ACCESS CONTROL: (2) Kantech Software-EntraPass Corporate Edition V8 USB key, or approved equal. Includes one server workstation and 2 ad (4) Kantech KITS (Or approved equal): Expansion kit includes KT-400 controller (1), KT-MUL-MT readers (4), TR1675 transfor Install (30) Card readers for In/Out function at each door (14) Additional Kantech (or approved equal) readers Drill trough walls to enable connections between interior and exterior of each (15) doors. Mount conduit on interior and exterior of each of (15) doors for wire runs. Install (15) Status Door contacts (3) Transformer Cover (2) Power Supply (4) Back Up Batteries (50) Access Key Fobs (1) Wiring and conduit Provide programming, training and testing of all equipment, on basic user functions, including Add/Delete credentials & remote doors functions to be used by Control room personnel. |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |