Similar Projects
Kate Drive to Corporate Drive Water Main Extension
Infrastructure
Bidding
Danville, KY 40422

Contract 3 - Water Meter Purchase
Infrastructure
Bidding
London, KY

Jeffersontown Public Works Administrative/Training Building Plumbing
Post-Bid
Jeffersontown, KY 40299

Water System Improvements Ph 11 - Zone Meter & River Crossing Installation Re-Bid
Post-Bid
Irvine, KY

4610--VHA Mar Cor Reverse Osmosis Water Purification BNOE | Sources Sought | 36U10120Q0029
Results

4610--VHA Mar Cor Reverse Osmosis Water Purification BNOE | Sources Sought | 36U10120Q0029
Results

Water and Sewer Infrastructure
Infrastructure
Pending Verification
$2,336,513 est. value
Pikeville, KY

AMR/AMI Water Meters and Existing Software Upgrades
Infrastructure, Alteration
Bidding
Cloverport, KY

Miscellaneous Water System Improvements - Rebid
Post-Bid
Paintsville, KY

Dudley Double-Seated Ball Valve with Actuator
Results
Less than $72,732 est. value
Edgewood, KY 41017

Main Street Water Main Replacement
Infrastructure
Bidding
$500,000 to $1,000,000 est. value
Shelbyville, KY

Chiller and Water Replacement at Rutherford Elementary School
Post-Bid
Louisville, KY 40214

Persimmon Sassafras Sugar Tree Walnut and Willow Water Main Replacement
Results
Less than $472,922 est. value
Erlanger, KY 41018

Third Street Water Line Relocation
Post-Bid
Maysville, KY

Tapping Saddles for PVC and Ductile Iron Pipe
Results
Louisville, KY 40202

Last Updated 12/17/2021 05:08 PM
Project Title

Water Hammer Control Upgrade

Physical Address View project details and contacts
City, State (County) Lexington, KY   (Fayette County)
Category(s) Sewer and Water, Single Trades
Sub-Category(s) Plumbing, Water Lines
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value Less than $30,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Lexington wishes to lower in the incoming water pressure to see if that can finally resolve the water hammer problem. The requested scope work Lexington has two parts. 1. Part One – remove the exterior RPZ backflow preventer and replace with a 3-inch Pressure Reducing Valve (PRV). Replace pipe and valves as needed to fit PRV into existing 4-inch water service configuration. 2. Part Two– install PRV bypass line.

Details

Division 22 - Plumbing, Common Work Results for Plumbing.
Division 33 - Utilities, Instrumentation and Control for Utilities, Water Utilities, Water Utility Distribution Piping, Water Utility Distribution Equipment, Disinfecting of Water Utility Distribution, Water Utility Storage Tanks.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents