Similar Projects
Isolation Rooms Ventilation
Alteration
Bidding
$25,000 est. value
Montezuma Creek, UT 84534

University of Utah Orthopedic Center (UUOC) Central Sterile Cart Washer - HVAC
Alteration
Bidding
$283,540 est. value
Salt Lake City, UT 84108

CM/GC Administration Building HVAC Renovation
Post-Bid
Farmington, UT 84025

Ingersoll Rand Compressed Air System Purchase and Install
Post-Bid

Sorenson Multi-Cultural Center Phase 2, Pool Air Handler Replacement
Results
Less than $1,099,944 est. value
Salt Lake City, UT 84104

Eccles HVAC Fans and Tab
Results
Less than $225,000 est. value
Sandy, UT

SD 100 HVAC Inverter Replacement
Post-Bid
Salt Lake City, UT

DFCM Construction - Pre-Qualified Mechanical Contractors-Farmington Bay Youth Center RTU Replacements
Results
$207,831 est. value
Farmington, UT 84025

Simmons Building HVAC Upgrade
Post-Bid
Kaysville, UT 84037

Kearn's Senior Center RTU HVAC Replacement
Results
$150,000 to $200,000 est. value
Kearns, UT 84118

Removal of 18 Existing Electric Furnaces and Air Conditioning Units and Installation of 18 New HVAC Gas Units
Post-Bid
Beaver, UT

ADC Pod C Heat Exchanger Replacement
Results
Salt Lake City, South Salt Lake, UT 84119

USDA-ARS-PWA In Logan, UT - Operation Maintenance Services
Post-Bid
Logan, UT

Archives C-6 Warehouse Freeport Center Redundant HVAC Humidity
Results
Less than $100,050 est. value
Clearfield, UT 84015

Hydraulic Test Stand Chiller
Post-Bid
Salt Lake City, UT 84116

Reported 06/04/2022 12:00 AM
Project Title

Grand County Courthouse HVAC 2022 Replacement

Physical Address View project details and contacts
City, State (County) Moab, UT 84532   (Grand County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Bidding, Construction Start Expected July 2022
Bids Due View project details and contacts
Estimated Value $300,000 [brand] Estimate
Plans Available from County Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Replace (4) Four HVAC rooftop units at the grand county courthouse, consisting of (1) one 4 ton unit, (2) two 7.5 ton units and (1) one 10 ton unit to replace the existing units. Existing Unit description RTU 7 Trane (Model# Z041024570)(Serial# YCD120B3HOEB)(Tonnage 10) Year 2001 RTU 3 Trane (Model# YCH092A3EHAOY000)(Serial#243100722L)(Tonnage 7.5)Year 2002 RTU 12 Lennox (Model# GCS16-513-125-3y)(Serial# 5692l02422)(Tonnage 4) Year 1992 RTU 2 Trane (Model# YCD090C3HOBE)(R02102203D)(Tonnage 7.5) Year 2000

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents