Similar Projects
Last Updated | 12/08/2022 12:03 PM |
Project Title | Existing Plant Rehabilitation Project |
Physical Address | View project details and contacts |
City, State (County) | Sunnyvale, CA 94087 (Santa Clara County) |
Category(s) | Sewer and Water |
Sub-Category(s) | Sewage Treatment Plant |
Contracting Method | Competitive Bids |
Project Status | Bidding, Construction start expected December 2022 |
Bids Due | View project details and contacts |
Estimated Value | $45,000,000 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | **As of December 8, 2022, this project has not yet been awarded. Anticipated award date is on February of 2023. In accordance with Drawings and Specifications prepared by Carollo Engineers, the Work includes furnishing of all labor, materials, tax, equipment, incidentals and services for the construction and completion of the Existing Plant Rehabilitation Project, Project No. UY-21-04. The Work includes but is not limited to: site work, installation of major process equipment, yard piping within the Water Pollution Control Plant boundaries, existing facility modification/demolition, electrical systems, instrumentation/control system improvements, and related systems and facilities. The Contract Time for the completion of all the Work of the Project is One Thousand Fifty (1,050) Calendar Days. Inquiries regarding further information about the Project may be directed to Lisa Vo, Principal Buyer, at LVo@sunnyvale.ca.gov (408) 730-7608. Including any data system whose only function is to transmit or receive information; excluding all other data systems or multiple systems which include control function or power supply; inclusion or exclusion of terminations and testings of conductors determined by their function; excluding fire alarm work when installed in raceways (including wire and cable pulling) and when performed on new or major remodel building projects or jobs for which the conductors for the fire alarm system are installed in conduit; excluding installation of raceway systems, line voltage work, industrial work, life-safety systems (all buildings having floors located more than 75' above the lowest floor level having building access); excluding energy management systems. |
||||||||||||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |