Reported | 12/14/2021 12:00 AM |
Project Title | J012--Fire and Smoke Damper Repairs Services |
Physical Address | View project details and contacts |
City, State (County) | Boston, MA 02132 (Suffolk County) |
Category(s) | Single Trades |
Sub-Category(s) | Fire Protection |
Contracting Method | Competitive Bids. |
Project Status | Request for Quotations |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The fire and smoke dampers to be repaired are listed in Attachment 1, Damper Inventory Report list. Based on the Damper Inventory Report list, the vendor shall provide the following replacement and repair services. Damper Repairs: The vendor shall provide damper repairs in accordance with the attached Damper Report (attachment A). The vendor shall replace all dampers in need of complete replacement with Dampers listed by Underwriters Laboratory as UL555 (Fire Dampers), UL555S (Smoke Dampers), UL555C (Ceiling Dampers). The vendor shall determine the proper rating, size, expansion clearance, retaining angle, sleeve requirements, duct to sleeve connections and location for the replacement damper. Re-Inspection Services: The Vendor shall perform the Inspection Services in a workmanlike manner. While performing such Inspection Services, the vendor shall utilize reasonable infection control procedures. Without limiting the foregoing, vendor shall adhere to Customer’s infection control risk assessments (“ICRAs). Damper Accessibility. Reasonable effort will be made to provide the vendor with accessibility to Dampers. However, vendor shall adhere to the following guidelines: a.If a duct penetrating a fire/smoke wall is accessible, but has no access panel, vendor shall cut and install an access panel, with Government’s approval, and carry out damper inspection as far as possible. b.If the only access point is longer than an arm’s reach away from the Damper, vendor shall perform a visual inspection to the limit allowable, including inspecting the frame for signs of kinking or twisting, looking for rust or build-up of any kind that may keep the Damper from closing, and looking for obvious obstructions, such as wire or conduit running through the damper. |
||||
Details |
|
||||
Bidder's List | View project details and contacts | ||||
Prospective Bidders | View project details and contacts | ||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |