Similar Projects
Roof Replacement - Student Union
Bidding
Arnold, MD

Baltimore Convention Center Planter Waterproofing
Bidding
$500,000 to $1,000,000 est. value
Baltimore, MD 21201

Roofing Repair and Maintenance
Post-Bid

Exterior Renovations, Observation Tower on Hart Miller Island
Post-Bid
Less than $50,000 est. value
Baltimore, MD

Replace Flat Roof
Results
$25,000 to $90,000 est. value
Laurel, MD

Shed Roof Replacement
Results
Less than $28,000 est. value
Hanover, MD 21076

Roof Replacement at Booker T. Washington Building 130
Bidding
Less than $3,347,905 est. value
Baltimore, MD 21217

Fire Station 5 Roof Replacement
- 7,419 SF
Post-Bid
$100,000 to $500,000 est. value
Baltimore, MD 21231

Roof Replacement - Cade Building
Results
Arnold, MD 21012

Roof Replacement at Benjamin Franklin Building 239
Bidding
Baltimore, MD 21225

Roof Replacement at People's Resource Center
Results
$100,000 to $500,000 est. value
Crownsville, MD 21032

Eastern Clinic Roof Replacement
- 17,740 SF
Bidding
$500,000 to $1,000,000 est. value
Baltimore, MD 21202

Indefinite Quantity Contract to Provide Roofing Work and Related Services
Results
Less than $15,000,000 est. value

Smith Island Roof Replacement
Bidding
Annapolis, MD

Roof Gutter Replacement
Results
Less than $50,000 est. value
Harmans, MD 21076

Reported 03/11/2021 12:00 AM
Project Title

Eastport Community Center Roof Replacement

Physical Address View project details and contacts
City, State (County) Annapolis, MD 21403   (Anne Arundel County)
Category(s) Single Trades
Sub-Category(s) Roofing
Contracting Method Competitive Bids.
Project Status Request for Proposals (RFPs)
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The Eastport Community Center has experienced an assortment of leaks over the years in all areas of the building. The 2019 Physical Needs Assessment and Replacement Analysis indicated that the Remaining Life of the roofs was 3 years and replacement was recommended within 1 year. This supports the need for complete replacement at this time, including re-sloping of new material to prevent ponding of water and directing water to drains and scuppers. Further, the gymnasium roof is EPDM with rock ballast which can be a potential hazard.

Details

13,976 SF.
Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents