Similar Projects
HVAC Water Treatment Chemicals, Service and Testing
Term Contract
Post-Bid
Cranston, RI

RISE Prep Mayoral Academy HVAC Maintenance Services
Post-Bid
Woonsocket, RI 02895

Dust Collection System
Results
Providence, RI

Powers Building - HVAC Terminal Box Control Upgrade Phase II
Results
North Providence, RI 02908

HVAC Maintenance Service
Post-Bid
North Providence, RI 02908

Police Station HVAC
Results
North Scituate, RI

HVAC Preventative Maintenance Program
Term Contract
Post-Bid
Central Falls, RI 02863

S114--Contract for Boilers and Cooling Towers Treatment
Results
Providence, RI 02908

Air Handler and Air Duct Cleaning
Post-Bid
Cranston, RI 02920

Second Floor Town Hall Air Conditioning
Results
North Scituate, RI 02857

Auditorium Condensing Unit Replacement
Post-Bid
North Scituate, RI 02857

Lincoln Rescue Station Front Street Heating Replacement
Results
Lincoln, RI 02865

Installation 2.5 Tom Mitsubishi A/C Split Replacement
Post-Bid
Cranston, RI 02920

Chiller Maintenance and Repair - Rhode Island College
Term Contract
Results
Providence, RI 02908

Generator Exhaust Stack
Post-Bid
$500,000 to $1,000,000 est. value
Providence, RI 02903

Last Updated 11/18/2020 09:10 AM
Project Title

Replacement of Air Control System for Police Station

Physical Address View project details and contacts
City, State (County) East Providence, RI 02914   (Providence County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

This scope of work outlines a complete replacement of the pneumatic control system, VAV box replacement, cleaning and air balancing of the Police Station's HVAC system. This work will ensure that the building is receiving the correct amount of outdoor air to the building occupants and will also improve comfort throughout the building. At this time the amount of outdoor air being delivered to the spaces is unknown and due to the condition of the VAV dampers, controls and coils it is very likely the minimum required outdoor air per building codes for the occupants is not being met. The recommended HVAC control system will include a graphic that will allow global adjustments of the ventilation rate of the police station to increase or decrease ventilation rates in response to the current pandemic.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents