Similar Projects
Fire Alarm Replacement & Installation Services
Bidding
Deerfield, NH

Fire Alarm System Upgrade at Derry Wastewater Treatment Plant
Post-Bid
Derry, NH

Complete Replacement of Fire Alarm System
Post-Bid
$4,000,000 to $6,000,000 est. value
Concord, NH

Fire Sprinkler Systems Testing and Inspection
Results
Brentwood, NH

Fire Inspection Services
Results
Dover, NH

Sprinkler Upgrade
Post-Bid
Tilton, NH 03276

Child Care Center Fire Sprinkler Upgrades
Results
Rochester, NH

Bureau of Bridge Maintenance
Post-Bid
Conway, NH 03813

Fire Extinguisher inspections
Term Contract
Results
Merrimack, NH 03054

Federal Building and Courthouse Fire Alarm Replacement Design/Build
Post-Bid
$1,000,000 to $4,500,000 est. value
Concord, NH 03303

Fire Alarm System Inspection and Testing
Term Contract
Results
Merrimack, NH 03054

Sprinkler Inspections
Term Contract
Results
Merrimack, NH

Fire Alarm and Fire Suppression Systems Services
Term Contract
Results
Farmington, NH 03835

Replacement of Raymond High School Fire Pump the Raymond High School
Results
Raymond, NH 03077

Fire Alarm Testing and Maintenance Services
Term Contract
Results
Bedford, NH

Reported 06/26/2020 12:00 AM
Project Title

Airline Terminal Fire Alarm System Upgrade at Manchester-Boston Regional Airport

Physical Address View project details and contacts
City, State (County) Manchester, NH 03103   (Hillsborough County)
Category(s) Single Trades
Sub-Category(s) Fire Protection
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value $1,500,000 to $2,200,000
Plans Available from Copy Center
Owner View project details and contacts
Architect View project details and contacts
Description

The project will provide either modification and technology upgrade or replacement of the existing Edwards/EST "IRC-3" fire alarm system that currently serves the main terminal building at the Airport. The base bid work will include replacement of existing fire alarm control equipment with new equipment panels which are compatibly-listed for use with the existing field devices and wiring that will remain. An allowable alternative approach would permit replacement of all existing EST equipment and field devices with that of an acceptable alternate manufacturer. Upon completion of the work, the complete modified system will be subject to acceptance testing by the installing contractor and system supplier in accordance with NFPA 72 requirements and as directed by the local Authorities Having Jurisdiction. The contractor must maintain an active fire alarm system during the upgrade or replacement.

Details

Division 21 - Fire Suppression.
Division 28 - Electronic Safety and Security, Fire Detection and Alarm.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents