Similar Projects
Plug and Play
New Construction
Conception
Detroit, MI 48201

Park Pavilion at Joy Park - Clinton Township
Bidding
Jackson, MI

Chris Taylor Alumni Field - New Concessions and Lockers
Post-Bid
Dowagiac, MI 49047

Don Johnson Fieldhouse Improvements
Post-Bid
Lansing, MI 48900

Lakeside Park Pavilion and Miscellaneous Improvements
Results
Less than $121,339 est. value
Port Huron, MI

Construct Track Pavilion - Battle Creek ANGB
New Construction - 600 SF
Results
$25,000 to $100,000 est. value
Battle Creek, MI

Awnings Waterworks Pavilion
Post-Bid
Harbor Beach, MI

Construction of Softball Press Box
Results
Alma, MI

Burton Shade Project - Shade Sail Structure
Post-Bid
Huntington Woods, MI

Harbor Farmers Market Pavilion
Results
Benton Harbor, MI

Burton Shade Project - Picnic Structure
Post-Bid
Huntington Woods, MI

GSD Design Build Davison Yard Canopy
Term Contract
Results
Detroit, MI

Grand Haven Sluka Field - Restroom and Concession Building
Post-Bid
Grand Haven, MI

TYC Lake Huron And Lake Erie Lodges Renovations
Results
Less than $196,442 est. value
Roscommon, MI

Exterior Renovation At Bobo Brazil Community Center
Post-Bid
Benton Harbor, MI

Reported 03/20/2019 12:00 AM
Project Title

Burton Shade Project - Single Slope Structure

Physical Address View project details and contacts
City, State (County) Huntington Woods, MI   (Oakland County)
Category(s) Entertainment/Recreation
Sub-Category(s) Misc. Recreational
Contracting Method Competitive Bids.
Project Status Request for Proposals (RFP)
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description All pipe columns, steel plates and steel columns shall conform to ASTM standards. Anchor bolts set in new concrete shall be A36 threaded rod, ASTM A-325, or A-307. B. All anchor bolts, nuts, and washers shall be hot dipped galvanized. All footing reinforcements shall conform to ASTM A-615 grade 60. All shop welds shall comply with the latest edition of the American Welding Society Specifications. Welding procedures shall comply with the AWS D1.1-AWS Structural Welding Code-Steel. All welds to be performed by AWS-certified welders. All welds shall be continuous where length is not given, unless otherwise noted on drawings. All fillet welds shall be a minimum of 3/16” unless otherwise noted. All steel shall be welded shut at terminations to prevent leakage. Field –welded connections are not acceptable. Metal primer shall be epoxy polyester hybrid. Apply TGIC polyester, UVinhibited weather resistant powder coat (minimum 2 mm thick). All columns to be factory-welded and watertight. No field-drilling to permeate water barrier. On-site sewing of fabric will not be accepted. Corners shall be reinforced with extra non-tear material and strap Perimeters containing cables shall be double row lock stitched.
Details
Division 13 - Special Construction.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents