Similar Projects
Last Updated | 12/21/2020 01:51 PM |
Project Title | Sanitary Sewer Improvements |
Physical Address | View project details and contacts |
City, State (County) | Cameron, WV (Marshall County) |
Category(s) | Sewer and Water |
Sub-Category(s) | Sanitary Sewers |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | 1 LS Mobilization/Demobilization, 1 LS Erosion and Sediment Control, 1 LS Reclamation of Disturbed Area, 375 LF 8" PVC SDR-35 Gravity Sewer Pipe (0'-6' Deep), 375 LF 8" PVC SDR35 Gravity Sewer Pipe (6'-9' Deep), 25 LF 8" PVC SDR-35 Gravity Sewer Pipe (9’ - Up), 260 LF 8" DI CL-52 Gravity Sewer Pipe (0'-6' Deep), 80 LF 8" DI CL-52 Gravity Sewer Pipe (6' - Up), 25 LF 12” DI CL-52 Storm Sewer Pipe, 450 LF 4" PVC SDR-35 Storm Sewer/ Service Lateral Pipe, 60 LF 4" DI CL-52 Service Lateral Pipe, 15 EA 8" X 4" PVC Wye Service Connection, 2 EA 8” X 4” DIP Wye Service Connection, 17 EA 4" Customer Cleanout and Reconnect, 5 EA 4" Customer Storm Sewer Cleanout, 3 EA Tie-in Existing Sewer Main, 1 EA Tie-in to Existing Manhole, 4 EA Cut and Plug Existing Main Sewer Line, 6 EA Remove and Replace 48" Diameter Manhole, 10 VF 48" Diameter Manhole Riser Section, 7 EA Type A Manhole Rehabilitation (Remove & Replace Frame and Cover with Water Tight Frame and Cover), 4 EA Type B Manhole Rehabilitation (Spray Line Interior, Remove & Replace Frame and Cover with Water Tight Frame and Cover), 30 LF WVDOH Type "B" Trench Repair, 475 LF WVDOH Type "C" Trench Repair, 14,000 SF 2” Gravel Drive Overlay, 270 LF Rip Rap Stream Bank Slope Protection, 1 EA WVDOH Type G Precast Storm Sewer Inlet, 20 LF Poured Concrete Ditch (Match Existing), 1 LS Control Panel Upgrade Allowance, 1 LS Remove and Replace Mechanical Bar Screen, 1 EA Spare Pump for Influent Pump Station, 1 LS Remove and Replace SBR Basin #1 & #2 Waste Sludge Pump, Guiderails and Base, 1 LS Flow Monitoring and Level Sensor Replacement, 1 LS Remove and Replace Decanter Actuators with VFD Operated Actuators and Local Control Box, 1 LS Remove and Replace Dissolved Oxygen Monitoring Equipment. |
||||
Details |
|
||||
Bidder's List | View project details and contacts | ||||
Prospective Bidders | View project details and contacts | ||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |