Similar Projects
Last Updated | 11/14/2019 11:19 AM |
Project Title | Add/Alter/Repair Vehicle Maintenance Facility 3325 |
Physical Address | View project details and contacts |
City, State (County) | Trenton, NJ 08641 (Mercer County) |
Category(s) | Transportation |
Sub-Category(s) | Misc. Structures |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $1,000,000 to $5,000,000 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The two projects are PTFL122091 Addition to Vehicle Maintenance Facility and PTFL129091 Alteration to Vehicle Maintenance Facility. The two Projects will be combined. The scope of the Alteration projects includes all renovations to the existing structure including the reroofing of that part of the building. The Addition portion of the building includes construction of all new spaces. The Addition Project work includes demolition of Storage Building 33-26, and renovation and expansion of the existing Vehicle Maintenance Facility Building 33-25, along with site preparation, grading and paving; utility connections, and other incidental related work. The demolition of Building 33-26 includes the complete removal of structure of the roof, walls, stairs, floors, foundations and utilities. The site is to be left ready for construction. It is anticipated that there are Asbestos Containing Materials within the existing Building 3326. The renovated and expanded Building 33-25 consists of a one (1) story office and shop structure. Renovations to Building 33-25 include removal of the existing wood framed asphalt shingle roof structure and renovation of all existing utilities and systems within the building as well as expanded facilities and systems to support the office area, shops and new refueler bay facilities. All existing overhead doors will be replaced. Site work includes grading and preparing the site; paving and site lighting; relocation of underground utilities, and connection to existing utilities, including but not limited to, water, electric, sewer, and communications. No requirements exist for this building for blast resistant design under either project. |
||||||||||||||||||
Details |
|
||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |