Similar Projects
Utility Monitoring and Control Systems
Post-Bid
Less than $2,100,000,000 est. value

Statewide Indefinite Delivery Contract for Mechanical / Plumbing Construction Services
Post-Bid

Annex Heat Pumps
Results
Darlington, SC

Bard Units
Term Contract
Results
SC

Thornwell HVAC Replacements
Post-Bid
Hartsville, SC 29550

North Hartsville Elementary Cafeteria 15 Ton Heat Pump
Results
Hartsville, SC 29550

SJE Building A AC Units
Post-Bid
Darlington, SC 29532

DCIT Room 510 AC Unit
Results
Darlington, SC 29532

SJE Kitchen AC Units
Post-Bid
Darlington, SC 29532

Hartsville Middle School Library Heat Pump
Results
Hartsville, SC 29550

HVAC Maintenance
Post-Bid
Hartsville, SC

St Johns Elementary Building B HVAC Units
Results
Darlington, SC 29532

DCIT AC Unit Automotive Shop Room 523
Post-Bid
Darlington, SC

St Johns Elementary HVAC Units
Results
Less than $225,000 est. value
Darlington, SC 29532

Provide and Install A Newtrane A/C Unit at Darlington Middle School Gym
Post-Bid
Darlington, SC 29532

Last Updated 05/24/2019 10:31 AM
Project Title

Mayo High School Room 304 AC Unit

Physical Address View project details and contacts
City, State (County) Darlington, SC 29532   (Darlington County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description Furnish and install a new 7.5 ton system heat pump in Room # 304 at Mayo High School, located at 405 Chestnut St, Darlington, SC. The new unit must be a Trane, Carrier, Bryant, or equivalent 5 ton 240 volt 3 phase heat pump. Disconnects will be replaced with new disconnects. The new unit must contain a 12kw to 15kw auxiliary heat. The new condenser must include hail guards. If hail guards are not factory installed they must be furnished and installed by the contractor. If curb foot print if different, contractor is responsible for providing a curb adapter. Unit has a single 240 three phase circuit feeding disconnects. If single point entry kit is not available an outside breaker box with the unit on one breaker and the heat strips on another will be required. Contractor must dispose of all old equipment and clean up all debris.
Details
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents