Similar Projects
Emergency Generator Maintenance Services
Alteration
Bidding
Ferguson, MO 63145

Hubbell LED Troffers Lighting
Post-Bid
Saint Louis, MO

Cold Aerosol ULV Generator
Alteration
Post-Bid
Olivette, MO 63132

Led Light Pole Fixtures
Results
Ballwin, MO

Grand Glaize WWTF Transformer and Gate Replacement
Alteration
Results
Saint Louis, MO

Replacement of Lighting
Alteration
Post-Bid
Florissant, MO 63031

Caulks Creek Pump Station B (P-751) Generator Installation (IR)
Alteration
Results
$174,000 est. value
Chesterfield, MO 63017

JC Penney Building Replace South Electrical Switch Gear
Alteration
Post-Bid
Less than $195,000 est. value
Saint Louis, MO 63121

Clinton Peabody Emergency Lighting Repairs
Alteration
Results
Saint Louis, MO 63104

Rab Lighting, High Bay Light Fixtures
Alteration
Post-Bid
Saint Louis, MO

Electrical - On Call Maintenance and Repair Services
Term Contract
Post-Bid
Crestwood, MO

Facilities Maintenance Services
Infrastructure, Alteration
Post-Bid
Saint Louis, MO

Emergency Generators 50 and 80 Replacement
Alteration
Post-Bid
$250,000 est. value
Ferguson, MO 63145

Conduct Tri-Annual Electrical Testing
Term Contract
Post-Bid
Bella Villa, Saint Louis, MO 63125

Single Phase Padmount Dual Voltage Transformers
Alteration
Post-Bid
MO

Last Updated 03/29/2022 08:13 AM
Project Title

Generator

Physical Address View project details and contacts
City, State (County) Sappington, MO 63127   (Saint Louis County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Replacement generator at the Public Works Garage at 3909 South Lindbergh, Saint Louis Missouri, 63127. Work will include the complete removal and replacement of the generator and automatic transfer switch (ATS) at Public Works Garage. The old Generator will remain with the city after removal. The Bidder will coordinate with the City if the existing concrete pad has to be modified to fit the footprint of the new generator. Reusing existing conduits. A complete installation & startup of this unit will be required to train City personnel on this unit including any maintenance items or programming. This generator shall be comparable to a Kohler 20REOZK diesel or GENERAC RD020. The generator shall be a minimum of a 20KW water-cooled diesel engine with a new 100 amp minimum transfer switch with a digital indoor/outdoor controller. Generator shall have weatherproof housing that is also sound attenuated with removable locking doors. Unit shall have all vibration isolators to keep vibration and noise at a minimum. A 70 maximum decibel level allowed. The outer enclosure shall be painted beige or light brown in color. The engine shall have a minimum of a 1000 watt 120 volt block heater installed. Also must have a self contained sub base diesel fuel tank that is capable of running the generator at least 20 hours at 75% load.

Details

Division 26 - Electrical, Packaged Generator Assemblies.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents