Project Title | Airport Industrial Access Road Water Line Relocation and Elm Avenue Water Line Abandonment and Miscellaneous Improvements |
Physical Address | View project details and contacts |
City, State (County) | Stillwater, OK 74074 (Payne County) |
Category(s) | Heavy and Highway, Sewer and Water |
Sub-Category(s) | Site Development, Water Lines |
Contracting Method | Competitive Bids |
Project Status | Contract Award, Construction start expected November 2021 |
Bids Due | View project details and contacts |
Estimated Value | $322,915 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | **As of Sept. 16, 2021, Danny Wick Excavating, LLC was the sole bidder and approved. The project will likely start November 2021. Sope of work to primarily include the following: Schedule A - Abandon 500 linear feet of 12-inch ductile iron water line and install 794 linear feet of 12-inch and 230 linear feet of 6-inch PVC water line along Airport Industrial Access Road. Schedule B - Remove a fire hydrant at the northwest corner of Main St. and Elm Ave., and install a new hydrant at southwest corner. Replace 6-inch gate valves at the corner of Elm Ave. and Duncan St., 5th Ave. and West St., and Miller Ave. and Lowry St., abandon existing 4-inch and 6-inch water lines on Elm Ave., Main St., Virginia St., Duncan St. and West St., and install new 6-inch water line and associated fittings at the Elm Ave. and Husband St. intersection. Questions please contact: Michael Stephenson at 405-742-8263 Email: mstephenson@stillwater.org All bonds and insurance required by the Contract Documents to be purchased and maintained by Owner or Contractor shall be obtained from surety or insurance companies that are duly licensed or authorized in the jurisdiction in which the Project is located to issue bonds or insurance policies for the limits and coverages so required. Such surety and insurance companies shall also meet such additional requirements and qualifications as may be provided in the Supplementary Conditions. Owner reserves the right to reject any or all Bids, or portions thereof, including without limitation, nonconforming, nonresponsive, unbalanced, or conditional Bids. Owner further reserves the right to reject the Bid of any Bidder whom it finds, after reasonable inquiry and evaluation, to not be responsible. |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
![]() Engineered Spec Sheet ![]() Architectural Plans ![]() Other Documents |