Similar Projects
Last Updated | 04/29/2021 03:49 AM |
Project Title | Safety Project/Milling and Resurfacing/Lighting/Traffic Signals |
Physical Address | View project details and contacts |
City, State (County) | State-Wide: FL |
Category(s) | Heavy and Highway |
Sub-Category(s) | Traffic Signalization |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $1,725,893 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Section 0001 Structures 0458- 1- 21 Bridge Deck Expansion Joint, Rehabilitation, Poured Joint With Backer Rod Lf 500.000 Section 0002 Roadway 0102- 14- Traffic Control Officer Hr 4,500.000 0102- 60- Work Zone Sign Ed 85,000.000 0102- 61- Business Sign Ea 6.000 0102- 62- Barrier Mounted Work Zone Sign- Index 11871/700-013 Ed 200.000 0102- 71- 13 Temporary Barrier, f&i, Low Profile, Concrete Lf 1,500.000 0102- 71- 15 Temporary Barrier, f&i, Anchored Lf 200.000 0102- 71- 16 Temporary Barrier, f&i, Free Standing Lf 150.000 0102- 71- 23 Temporary Barrier, Relocate, Low Profile Concrete Lf 400.000 0102- 74- 1 Channelizing Device- Types i, Ii, Di, Vp, Drum, Or Lcd Ed 220,000.000 0102- 74- 8 Channelizing Device- Pedestrian Lcd (Longitudinal Channelizing Device) Fd 13,400.000 0102- 76- Arrow Board / Advance Warning Arrow Panel Ed 3,500.000 0102- 78- Temporary Raised/Retroreflective Pavement Marker Ea 35.000 0102- 99- Portable Changeable Message Sign, Temporary Ed 6,200.000 0102-104- Temporary Signalization And Maintenance, Intersection Ed 650.000 0102-107- 1 Temporary Traffic Detection And Maintenance, Intersection Ed 700.000 0102-115- Type Iii Barricade Ed 3,600.000 0102-150- 1 Portable Regulatory, Sign Ed 100.000 0102-150- 2 Radar Speed Display Unit Ed 100.000 0102-909- Temporary Raised Rumble Strips- Per Day, Includes All Sets And Relocations Da 2.000 0102-913- 11 Removable Tape, Black, Solid 6" Gm 0.500 0102-913- 21 Removable Tape, White, Solid 6" Gm 0.500 0102-913- 23 Removable Tape, White, 24" Stop Bar Lf 110.000 0102-913- 24 Removable Tape, White, 12" Crosswalk Lf 500.000 0104- 10- 3 Sediment Barrier Lf 23,000.000 0104- 12- Staked Turbidity Barrier- Nylon Reinforced Pvc Lf 600.000 0104- 18- Inlet Protection System Ea 200.000 0107- 1- Litter Removal Ac 50.000 0107- 2- Mowing Ac 30.000 0110- 2- 1 Clearing & Grubbing (Push Button Contract) Ac 30.000 0110- 4- 10 Removal Of Existing Concrete Sy 3,500.000 0120- 1- Regular Excavation Cy 2,200.000 0120- 2- 2 Borrow Excavation, Truck Measure Cy 250.000 0120- 3- Lateral Ditch Excavation Cy 1,400.000 0120- 6- Embankment Cy 3,000.000 0160- 4- Type b Stabilization Sy 5,000.000 0285-701- Optional Base, Base Group 01 Sy 1.000 0285-702- Optional Base, Base Group 02 Sy 1.000 0285-709- Optional Base, Base Group 09 Sy 1.000 0285-710- Optional Base, Base Group 10 Sy 3,500.000 0285-712- Optional Base, Base Group 12 Sy 550.000 0327- 70- 1 Milling Existing Asphalt Pavement, 1" Avg Depth Sy 1,500.000 0327- 70- 4 Milling Existing Asphalt Pavement, 3" Avg Depth Sy 75,000.000 0327- 70- 5 Milling Existing Asphalt Pavement, 2" Avg Depth Sy 7,500.000 0327- 70- 6 Milling Existing Asphalt Pavement, 1 1/2" Avg Depth Sy 75,000.000 0327- 70- 8 Milling Existing Asphalt Pavement, 2 1/2" Avg Depth Sy 3,500.000 0327- 70- 11 Milling Existing Asphalt Pavement, 2 1/4" Avg Depth Sy 50,000.000 0327- 70- 13 Milling Existing Asphalt Pavement, 1 3/4" Avg Depth Sy 32,000.000 0334- 1- 52 Superpave Asphaltic Concrete, Traffic b, Pg76-22 Tn 100.000 0334- 1- 53 Superpave Asphaltic Concrete, Traffic c, Pg76-22 Tn 6,500.000 0334- 1- 54 Superpave Asphaltic Concrete, Traffic d, Pg76-22 Tn 100.000 0337- 7- 25 Asphalt Concrete Friction Course, Inc Bit, Fc-5, Pg 76-22 Tn 100.000 0337- 7- 83 Asphalt Concrete Friction Course,Traffic c, Fc-12.5, Pg 76- 22 Tn 16,000.000 0337- 7- 85 Asphalt Concrete Friction Course,Traffic d, Fc-12.5, Pg 76- 22 Tn 100.000 0339- 1- Miscellaneous Asphalt Pavement Tn 70.000 0350- 3- 1 Plain Cement Concrete Pavement, 6" Sy 21.000 0425- 1-351 Inlets, Curb, Type p-5, <10' Ea 1.000 0425- 1-361 Inlets, Curb, Type p-6, <10' Ea 1.000 0425- 1-451 Inlets, Curb, Type j-5, <10' Ea 1.000 0425- 1-461 Inlets, Curb, Type j-6, <10' Ea 1.000 0425- 1-511 Inlets, Dt Bot, Type b, <10' Ea 1.000 0425- 1-521 Inlets, Dt Bot, Type c,<10' Ea 1.000 0425- 1-541 Inlets, Dt Bot, Type d, <10' Ea 1.000 0425- 1-551 Inlets, Dt Bot, Type e, <10' Ea 1.000 0425- 1-701 Inlets, Gutter, Type s, <10' Ea 1.000 0425- 2- 41 Manholes, p-7, <10' Ea 1.000 0425- 2- 43 Manholes, p-7, Partial Ea 1.000 0425- 2- 61 Manholes, p-8, <10' Ea 1.000 0425- 2- 63 Manholes, p-8, Partial Ea 1.000 0425- 2- 71 Manholes, j-7, <10' Ea 1.000 0425- 2- 91 Manholes, j-8, <10' Ea 1.000 0425- 4- Inlets, Adjust Ea 1.000 0425- 5- Manhole, Adjust Ea 24.000 0425- 5- 1 Manhole, Adjust, Utilities Ea 3.000 0425- 6- Valve Boxes, Adjust Ea 12.000 0430-174-118 Pipe Culvert, Optional Material, Round, 18"Sd Lf 1.000 0430-174-124 Pipe Culvert, Optional Material, Round, 24"Sd Lf 1.000 0430-174-218 Pipe Culvert, Optional Material, Other Shape - Ellip/Arch, 18"Sd Lf 1.000 0430-174-224 Pipe Culvert, Optional Material, Other Shape - Ellip/Arch, 24"Sd Lf 1.000 0430-175-118 Pipe Culvert,Optional Material,Round, 18"s/Cd Lf 1.000 0430-175-124 Pipe Culvert,Optional Material,Round, 24"s/Cd Lf 1.000 0430-175-130 Pipe Culvert, Opt Material, Round, 30"s/Cd Lf 1.000 0430-175-218 Pipe Culvert,Optional Material,Other-Elip/Arch, 18"s/Cd Lf 1.000 0430-175-224 Pipe Culvert,Optional Material,Other Shape-Elip/Arch, 24"s/Cd Lf 1.000 0430-982-125 Mitered End Section, Optional Round, 18" Cd Ea 1.000 0430-982-129 Mitered End Section, Optional Round, 24" Cd Ea 1.000 0430-982-133 Mitered End Section, Optional Round, 30" Cd Ea 1.000 0430-984-125 Mitered End Section, Optional Round, 18" Sd Ea 1.000 0430-984-129 Mitered End Section, Optional Round, 24" Sd Ea 1.000 0430-984-625 Mitered End Sect, Optional - Elliptical / Arch, 18" Sd Ea 1.000 0430-984-629 Mitered End Sect, Optional - Elliptical / Arch, 24" Sd Ea 1.000 0515- 1- 2 Pipe Handrail - Guiderail, Aluminum Lf 20.000 0515- 2-311 Pedestrian/ Bicycle Railing, Aluminum Only,42" Type 1 Lf 40.000 0515- 2-313 Pedestrian / Bicycle Railing, Aluminum, 42" Type 3 Lf 1.000 0520- 1- 7 Concrete Curb & Gutter, Type e Lf 350.000 0520- 1- 10 Concrete Curb & Gutter, Type f Lf 2,000.000 0520- 2- 2 Concrete Curb, Type b Lf 5.000 0520- 2- 4 Concrete Curb, Type d Lf 6,000.000 0520- 3- Valley Gutter- Concrete Lf 5.000 0520- 5- 11 Traffic Separator Concrete-Type i, 4' Wide Lf 2,600.000 0520- 5- 12 Traffic Separator Concrete-Type i, 6' Wide Lf 5.000 0520- 5- 41 Traffic Separator Concrete- Type Iv, 4' Wide Lf 20.000 0520- 5- 42 Traffic Separator Concrete- Type Iv, 6' Wide Lf 1.000 0520- 6- Shoulder Gutter- Concrete Lf 500.000 0520- 70- Concrete Traffic Separator, Special- Variable Width Sy 2,500.000 0522- 1- Concrete Sidewalk And Driveways, 4" Thick Sy 150.000 0522- 2- Concrete Sidewalk And Driveways, 6" Thick Sy 2,000.000 0524- 1- 2 Concrete Ditch Pavement, Non Reinforced, 4" Sy 70.000 0527- 2- Detectable Warnings Sf 650.000 0536- 1- 1 Guardrail -Roadway, General Tl-3 Lf 700.000 0536- 1- 3 Guardrail- Roadway, Double Face Lf 40.000 0536- 73- Guardrail Removal Lf 1.000 0536- 85- 20 Guardrail End Treatment- Trailing Anchorage Ea 1.000 0536- 85- 24 Guardrail End Treatment- Parallel Approach Terminal Ea 2.000 0536- 85- 27 Guardrail End Treatment- Double Face Approach Termina Ea 1.000 0546- 72- 1 Ground-In Rumble Strips, 16" Gm 1.000 0546- 72- 2 Ground-In Rumble Strips, 8" Cylindrical Gm 1.000 0546- 72- 3 Ground-In Rumble Strips, 8" Sinusoidal Gm 2.000 0570- 1- 1 Performance Turf Sy 5,000.000 0570- 1- 2 Performance Turf, Sod Sy 5,000.000 0570- 1- 3 Performance Turf, Sod And Soil- Shoulder Treatment Index 570-010 Sy 5,000.000 0908-333- 15 High Friction Surface Course, Project 440552-3-52-01 Sy 25,000.000 Section 0003 Signing 0700- 1- 11 Single Post Sign, f&i Ground Mount, Up To 12 Sf As 60.000 0700- 1- 12 Single Post Sign, f&i Ground Mount, 12-20 Sf As 5.000 0700- 1- 13 Single Post Sign, f&i Ground Mount, 21-30 Sf As 1.000 0700- 1- 50 Single Post Sign, Relocate As 100.000 0700- 1- 60 Single Post Sign, Remove As 500.000 0700- 2- 50 Multi- Post Sign, Ground Mount, Relocate As 1.000 0700- 3-101 Sign Panel, Furnish & Install Ground Mount, Up To 12 Sf Ea 100.000 0700- 3-102 Sign Panel, Furnish & Install Ground Mount, 12-20 Sf Ea 1.000 0700- 3-201 Sign Panel, Furnish & Install Overhead Mount, Up To 12 Sf Ea 50.000 0700- 3-202 Sign Panel, Furnish & Install Overhead Mount, 12-20 Sf Ea 20.000 0700- 3-501 Sign Panel, Relocate, Up To 12 Sf Ea 3.000 0700- 3-502 Sign Panel, Relocate, 12-20 Sf Ea 10.000 0700- 3-601 Sign Panel, Remove, Up To 12 Sf Ea 1.000 0700- 3-602 Sign Panel, Remove, 12-20 Sf Ea 1.000 0700- 3-603 Sign Panel, Remove, 21-30 Sf Ea 1.000 0700- 5- 22 Internally Illuminated Sign, Furnish & Install, Overhead Mount, 12-18 Sf Ea 20.000 0700- 5- 50 Internally Illuminated Sign, Relocate Ea 1.000 0700- 6- 11 Highlighted Sign, f&i Ground Mount- Ac Powered, Up To 12 Sf As 1.000 0700- 6- 12 Highlighted Sign, f&i Ground Mount- Ac Powered, 12-20 Sf As 1.000 0700- 6- 21 Highlighted Sign, f&i Ground Mount- Solar Powered, Up To 12 Sf As 40.000 0700- 6- 22 Highlighted Sign, f&i Ground Mount- Solar Powered, 12-20 Sf As 1.000 0700- 8-231 Front Access Dynamic Message Sign, Furnish & Installwithout Ups, Full Color, Up To 12 Sf Ea 1.000 0700- 11-121 Electronic Display Sign, Furnish & Install Ground Mountac Powered, Electronic Regulatory Sign, Up To 12 Sf As 2.000 0700- 11-131 Electronic Display Sign, Furnish & Install Ground Mountac Powered, Speed Feedback Sign, Up To 12 Sf As 10.000 0700- 11-132 Electronic Display Sign, Furnish & Install Ground Mountac Powered, Speed Feedback Sign, 12-20 Sf As 1.000 0700- 11-231 Electronic Display Sign, Furnish & Install Ground Mountsolar Power, Speed Feedback, Up To 12 Sf As 1.000 0700- 11-232 Electronic Display Sign, Furnish & Install Ground Mountsolar Power, Speed Feedback, 12-20 Sf As 10.000 0700- 11-391 Electronic Display Sign, Furnish & Install Overhead Mount- Ac Powered, Blank Out Sign, Up To 12 Sf As 1.000 0700- 12- 11 Sign Beacon, f&i Ground Mount- Ac Powered, One Beacon As 10.000 0700- 12- 12 Sign Beacon, f&i Ground Mount- Ac Powered, Two Beacons As 1.000 0700- 12- 22 Sign Beacon, f&i Ground Mount- Solar Powered, Two Beacons As 1.000 0700- 12- 31 Sign Beacon, f&i Overhead Mount, One Beacon As 1.000 0700- 12- 32 Sign Beacon, f&i Overhead Mount, Two Beacons As 1.000 0700- 13- 15 Retroreflective Sign Strip- Furnish And Install, 5' Ea 1.000 0701- 17-201 Profiled Thermoplastic,Standard- Concrete Surfaces, Yellow, Solid,6" Gm 8.200 0701- 17-221 Profiled Thermoplastic,Standard- Concrete Surfaces, Yellow, Skip,6" Gm 2.500 0701- 18-101 Profiled Thermoplastic,Standard- Asphalt Surfaces, White, Solid,6" Gm 10.000 0701- 18-201 Profiled Thermoplastic,Standard- Asphalt Surfaces, Yellow, Solid,6" Gm 1.000 0701- 18-221 Profiled Thermoplastic,Standard- Asphalt Surfaces, Yellow, Skip,6" Gm 0.500 0705- 10- 1 Object Marker, Type 1 Ea 10.000 0705- 10- 2 Object Marker, Type 2 Ea 1.000 0705- 10- 3 Object Marker, Type 3 Ea 1.000 0705- 10- 4 Object Marker, Type 4 Ea 1.000 0705- 11- 1 Delineator, Flexible Tubular Ea 50.000 0705- 11- 3 Delineator, Flexible High Visibility Median Ea 20.000 0706- 1- 1 Raised Pavement Marker, Type b Without Final Surface Markings Ea 6,000.000 0706- 1-103 Raised Pavement Marker, Type f Internally Illuminated, Project 440552-3-52-01 Ea 3,500.000 0710- 11-101 Painted Pavement Markings, Standard, White, Solid, 6" Gm 10.000 0710- 11-102 Painted Pavement Markings, Standard, White, Solid For Interchange And Urban Island, 8" Gm 3.000 0710- 11-103 Painted Pavement Markings, Standard, White, Solid For Interchange Markings, 12" Gm 3.000 0710- 11-123 Painted Pavement Markings, Standard, White, Solid For Crosswalk And Roundabout, 12" Lf 4,000.000 0710- 11-124 Painted Pavement Markings, Standard, White, Solid For Diagonal Or Chevron, 18" Lf 5,000.000 0710- 11-125 Painted Pavement Markings, Standard, White, Solid For Stop Line Or Crosswalk, 24" Lf 4,000.000 0710- 11-131 Painted Pavement Markings, Standard, White, Skip, 10-30 Or 3-9 Skip, 6" Wide Gm 10.000 0710- 11-133 Painted Pavement Marking, Standard,White, 3'-9' Skip Drop Line And Approach To Toll Plaza, 12" Wide, Gm 5.000 0710- 11-141 Painted Pavement Markings, Standard, White, 2-4 Dotted Guideline/ 6-10 Dotted Extension, 6" Gm 10.000 0710- 11-160 Painted Pavement Markings, Standard, White, Message Or Symbol Ea 100.000 0710- 11-170 Painted Pavement Markings, Standard, White, Arrows Ea 150.000 0710- 11-180 Painted Pavement Markings, Standard, White, Yield Line Lf 1.000 0710- 11-190 Painted Pavement Markings, Standard, White, Island Nose Sf 1.000 0710- 11-201 Painted Pavement Markings, Standard, Yellow, Solid, 6" Gm 15.000 0710- 11-202 Painted Pavement Markings, Standard, Yellow, Solid For Interchange And Urban Island, 8" Gm 1.000 0710- 11-224 Painted Pavement Markings, Standard, Yellow, Solid For Diagonal Or Chevron, 18" Lf 3,000.000 0710- 11-231 Painted Pavement Markings, Standard, Yellow, Skip, 6" Gm 10.000 0710- 11-241 Painted Pavement Markings, Standard, Yellow, 2-4 Dotted Guideline/6-10 Dotted Extension, 6" Gm 8.000 0710- 11-290 Painted Pavement Markings, Standard, Yellow, Island Nose Sf 500.000 0710- 11-331 Painted Pavement Markings, Standard,Black, Skip, 6" Gm 1.000 0710- 11-421 Painted Pavement Markings, Standard, Blue, Solid For Parking Lot- Accessible Markings, 6" Lf 1.000 0711- 11-102 Thermoplastic, Standard, White, Solid, 8" For Interchange And Urban Island Gm 1.000 0711- 11-103 Thermoplastic, Standard, White, Solid, 12" For Interchange Markings Gm 1.000 0711- 11-123 Thermoplastic, Standard, White, Solid, 12" For Crosswalk And Roundabout Lf 8,000.000 0711- 11-124 Thermoplastic, Standard, White, Solid, 18" For Diagonals And Chevrons Lf 4,500.000 0711- 11-125 Thermoplastic, Standard, White, Solid, 24" For Stop Line And Crosswalk Lf 2,500.000 0711- 11-141 Thermoplastic, Standard, White, 2-4 Dotted Guideline/ 6-10 Gap Extension, 6" Gm 5.000 0711- 11-160 Thermoplastic, Standard, White, Message Or Symbol Ea 40.000 0711- 11-170 Thermoplastic, Standard, White, Arrow Ea 200.000 0711- 11-180 Thermoplastic, Standard, White, Yield Line Lf 1.000 0711- 11-224 Thermoplastic, Standard, Yellow, Solid, 18" For Diagonal Or Chevron Lf 2,500.000 0711- 11-241 Thermoplastic, Standard, Yellow, 2-4 Dotted Guide Line /6- 10 Dotted Extension Line, 6" Gm 1.000 0711- 14-123 Thermoplastic, Preformed, White, Solid, 12" For Crosswalk Lf 70.000 0711- 14-125 Thermoplastic, Preformed, White, Solid, 24" For Crosswalk Lf 2,500.000 0711- 14-160 Thermoplastic, Preformed, White, Message Ea 10.000 0711- 14-170 Thermoplastic, Preformed, White, Arrow Ea 10.000 0711- 15-101 Thermoplastic, Standard-Open Graded Asphalt Surfaces White, Solid, 6" Gm 5.000 0711- 15-102 Thermoplastic, Standard-Open Graded Asphalt Surfaces, White, Solid, 8" Gm 1.000 0711- 15-131 Thermoplastic, Standard-Open Graded Asphalt Surfaces, White, Skip, 6",10-30 Skip Or 3-9 Lane Drop Gm 6.000 0711- 15-201 Thermoplastic, Standard-Open Graded Asphalt Surfaces, Yellow, Solid, 6" Gm 4.000 0711- 15-231 Thermoplastic, Standard-Open Graded Asphalt Surfaces, Yellow, Skip, 6" Gm 0.100 0711- 16-101 Thermoplastic, Standard-Other Surfaces, White, Solid, 6" Gm 6.000 0711- 16-102 Thermoplastic, Standard-Other Surfaces, White, Solid, 8" Gm 1.000 0711- 16-131 Thermoplastic, Standard-Other Surfaces, White, Skip, 6",10-30 Skip Or 3-9 Lane Drop Gm 1.000 0711- 16-133 Thermoplastic, Standard-Other Surfaces White, Skip, 12"- Approach To Toll Plaza Or 3-9 Lane Drop Gm 1.000 0711- 16-201 Thermoplastic, Standard-Other Surfaces, Yellow, Solid, 6" Gm 5.000 0711- 16-202 Thermoplastic, Standard-Other Surfaces, Yellow, Solid, 8" Gm 0.100 0711- 16-231 Thermoplastic, Standard-Other Surfaces, Yellow, Skip, 6" Gm 1.000 0711- 17- 1 Thermoplastic, Remove Existing Thermoplastic Pavement Markings- Surface To Remain Sf 21,600.000 0713-107- Preformed/Permanent Tape, Remove Sf 25,000.000 0920-714- 25 Green Colored Pavement Markings, Bike Lane, Project 440552-3-52-01 Sf 2,000.000 Section 0004 Lighting 0635- 2- 11 Pull & Splice Box, f&i, 13" x 24" Cover Size Ea 200.000 0635- 2- 12 Pull & Splice Box, f&i, 24" x 36" Cover Size Ea 10.000 0715- 1- 11 Lighting Conductors, f&i, Insulated, No. 10 Or < Lf 1.000 0715- 1- 12 Lighting Conductors, f&i, Insulated, No.8 - 6 Lf 10,000.000 0715- 1- 13 Lighting Conductors, f&i, Insulated, No 4 To No 2 Lf 500.000 0715- 1- 14 Lighting Conductors, f&i, Insulated, No 1 To No 0 Lf 1.000 0715- 1- 60 Lighting Conductors, Remove & Dispose, Contractor Owns Lf 1.000 0715- 4- 11 Light Pole Complete, Furnish & Install Standard Pole Standard Foundation, 30' Mounting Height Ea 1.000 0715- 4- 12 Light Pole Complete, Furnish & Install Standard Pole Standard Foundation, 35' Mounting Height Ea 1.000 0715- 4- 13 Light Pole Complete, Furnish & Install Standard Pole Standard Foundation, 40' Mounting Height Ea 1.000 0715- 4- 14 Light Pole Complete, Furnish & Install Standard Pole Standard Foundation, 45' Mounting Height Ea 1.000 0715- 4- 15 Light Pole Complete, Furnish & Install Standard Pole Standard Foundation, 50' Mounting Height Ea 1.000 0715- 4- 60 Light Pole Complete, Relocate Ea 1.000 0715- 4- 70 Light Pole Complete, Remove Pole And Foundation Ea 1.000 0715- 5- 21 Luminaire & Bracket Arm, Replace Luminaire And Arm On Existing Pole Ea 1.000 0715- 5- 31 Luminaire & Bracket Arm- Aluminum, Furnish & Install New Luminaire And Arm On New/Existing Pole Ea 1.000 0715- 5- 51 Luminaire & Bracket Arm, Remove Luminaire And Arm; Pole Remains Ea 1.000 0715- 7- 11 Load Center, f&i, Secondary Voltage Ea 1.000 0715- 7- 41 Load Center, Remove, Secondary Voltage Ea 1.000 0715- 11-115 Luminaire, f&i, Roadway, Wall Mount Ea 1.000 0715- 11-211 Luminaire, f&i- Replace Existing Luminaire On Existing Pole/Arm, Roadway, Cobra Head Ea 1.000 0715- 11-213 Luminaire, f&i- Replace Existing Luminaire On Existing Pole/Arm, Roadway, Pole Top Ea 1.000 0715- 11-216 Luminaire, f&i- Replace Existing Luminaire On Existing Pole/Arm, Roadway, Pendant/Teardrop Ea 6.000 0715-500- 1 Pole Cable Distribution System, Furnish And Install, Conventional Ea 1.000 0715-500- 3 Pole Cable Distribution System, Wall Mount Ea 1.000 0715-511-130 Light Pole Complete- Special Design, f&i, Single Arm Shoulder Mount, Aluminum, 30' Ea 14.000 0715-511-140 Light Pole Complete- Special Design, f&i, Single Arm Shoulder Mount, Aluminum, 40' Ea 140.000 0715-511-335 Light Pole Complete- Special Design, f&i, Single Arm Shoulder Mount, Concrete, 35' Ea 6.000 0715-511-345 Light Pole Complete- Special Design, f&i, Single Arm Shoulder Mount, Concrete, 45' Ea 30.000 Section 0005 Signalization 0630- 2- 11 Conduit, Furnish & Install, Open Trench Lf 700.000 0630- 2- 12 Conduit, Furnish & Install, Directional Bore Lf 16,000.000 0630- 2- 14 Conduit, Furnish & Install, Aboveground Lf 100.000 0632- 7- 1 Signal Cable- New Or Reconstructed Intersection, Furnish & Install Pi 10.000 0632- 7- 2 Signal Cable- Repair/Replace/Other, Furnish & Install Lf 100.000 0632- 7- 4 Signal Cable, Adjust Pi 1.000 0632- 7- 6 Signal Cable, Remove- Intersection Pi 1.000 0632- 7- 7 Signal Cable, Remove- Outside Of Intersection Lf 500.000 0634- 4-151 Span Wire Assembly, f&i, Two Point, Perpendicular Pi 1.000 0634- 4-152 Span Wire Assembly, f&i, Two Point, Diagonal Pi 1.000 0634- 4-153 Span Wire Assembly, f&i, Two Point, Box Or Drop Box Pi 1.000 0634- 4-600 Span Wire Assembly, Remove- Poles Remain Pi 1.000 0635- 2- 11 Pull & Splice Box, f&i, 13" x 24" Cover Size Ea 200.000 0635- 2- 12 Pull & Splice Box, f&i, 24" x 36" Cover Size Ea 10.000 0635- 2- 13 Pull & Splice Box, f&i, 30" x 60" Rectangular Or 36" Round Cover Size Ea 1.000 0635- 2- 30 Pull & Splice Box, Install Ea 1.000 0639- 1-112 Electrical Power Service, f&i, Overhead Meter Purchased By Contractor From Power Company As 10.000 0639- 1-113 Electrical Power Service, f&i, Overhead Meter Not Required As 1.000 0639- 1-121 Electrical Power Service, f&i, Underground, Meter Furnished By Power Company As 1.000 0639- 1-122 Electrical Power Service, f&i, Underground, Meter Purchased By Contractor As 1.000 0639- 1-123 Electrical Power Service, f&i, Underground, Meter Not Required As 10.000 0639- 2- 1 Electrical Service Wire, Furnish & Install Lf 1,500.000 0639- 2- 6 Electrical Service Wire, Remove Lf 1.000 0639- 6- 1 Electrical Power Service- Transformer Furnish & Install Ea 1.000 0641- 2- 11 Prestressed Concrete Pole, f&i, Type p-Ii Pedestal Ea 20.000 0641- 2- 12 Prestressed Concrete Pole, f&i, Type p-Ii Service Pole Ea 1.000 0641- 2- 16 Prestressed Concrete Pole, f&i, Type p-Vi Ea 1.000 0641- 2- 17 Prestressed Concrete Pole, f&i, Type p-Vii Ea 1.000 0641- 2- 18 Prestressed Concrete Pole, f&i, Type p-Viii Ea 1.000 0641- 2- 70 Prestressed Concrete Pole, Shallow Pole Removal- Pole 30' And Greater Ea 1.000 0646- 1- 11 Aluminum Signals Pole, Pedestal Ea 20.000 0646- 1- 12 Aluminum Signals Pole, Furnish & Install Pedestrian Detector Post Ea 1.000 0646- 1- 40 Aluminum Signals Pole, Relocate Ea 1.000 0646- 1- 60 Aluminum Signals Pole, Remove Ea 1.000 0646- 2-115 Aluminum Pole- Index 695-001, Furnish & Install, 15' Ea 4.000 0649- 1- 63 Steel Strain Pole, Remove, Shallow Foundation Removal, Bolt On Attachment Ea 1.000 0649- 21- 1 Steel Mast Arm Assembly, Furnish And Install, Single Arm 30' Ea 1.000 0649- 21- 2 Steel Mast Arm Assembly, Furnish And Install, Double Arm 30'-30' Ea 1.000 0649- 21- 3 Steel Mast Arm Assembly, Furnish And Install, Single Arm 40' Ea 1.000 0649- 21- 5 Steel Mast Arm Assembly, Furnish And Install, Double Arm 40'-40' Ea 1.000 0649- 21- 6 Steel Mast Arm Assembly, Furnish And Install, Single Arm 50' Ea 1.000 0649- 21- 9 Steel Mast Arm Assembly, Furnish And Install, Double Arm 50'-50' Ea 1.000 0649- 21- 10 Steel Mast Arm Assembly, Furnish And Install, Single Arm 60' Ea 1.000 0649- 21- 13 Steel Mast Arm Assembly, Furnish And Install, Double Arm 60'-50' Ea 5.000 0649- 21- 15 Steel Mast Arm Assembly, Furnish And Install, Single Arm 70' Ea 5.000 0649- 21- 18 Steel Mast Arm Assembly, Furnish And Install, Double Arm 70'-50' Ea 1.000 0649- 21- 20 Steel Mast Arm Assembly, Furnish And Install, Double Arm 70'-70' Ea 1.000 0649- 21- 21 Steel Mast Arm Assembly, Furnish And Install, Single Arm 78' Ea 1.000 0649- 21- 25 Steel Mast Arm Assembly, Furnish And Install, Double Arm 78'-60' Ea 1.000 0649- 21- 27 Steel Mast Arm Assembly, Furnish And Install, Double Arm 78'-78' Ea 1.000 0649- 26- 3 Steel Mast Arm Assembly, Remove, Shallow Foundationbolt On Attachment Ea 6.000 0649- 26- 7 Steel Mast Arm Assembly, Remove, Remove Arm And Attachments; Pole Remains Ea 6.000 0650- 1- 11 Vehicular Traffic Signal, Furnish & Install Aluminum, 1 Section, 1 Way As 1.000 0650- 1- 14 Vehicular Traffic Signal, Furnish & Install Aluminum, 3 Section, 1 Way As 100.000 0650- 1- 16 Vehicular Traffic Signal, Furnish & Install Aluminum, 4 Section, 1 Way As 1.000 0650- 1- 19 Vehicular Traffic Signal, Furnish & Install Aluminum, 5 Section Cluster, 1 Way As 1.000 0650- 1- 44 Vehicular Traffic Signal, Furnish & Install Programmable, 3 Section, 1 Way As 20.000 0650- 1- 60 Vehicular Traffic Signal, Remove- Poles To Remain As 1.000 0650- 1- 70 Vehicular Traffic Signal, Relocate- Includes Removal And Reinstallation As 4.000 0653- 1- 11 Pedestrian Signal, Furnish & Install Led Countdown, 1 Way As 20.000 0653- 1- 12 Pedestrian Signal, Furnish & Install Led Countdown, 2 Ways As 10.000 0653- 1- 60 Pedestrian Signal, Remove Ped Signal- Pole/Pedestal To Remain As 6.000 0654- 2- 11 Midblock Cross: Rectangular Rapid Flashing Beacon, Furnish & Install- Ac Power, Complete Sign Assemblysingle Direction As 1.000 0654- 2- 21 Rectangular Rapid Flashing Beacon, Furnish & Installsolar Powered, Complete Sign Assembly- Single Direction As 1.000 0654- 2- 22 Rectangular Rapid Flashing Beacon, Furnish & Installsolar Powered, Complete Sign Assembly- Back To Back As 1.000 0654- 2- 60 Rectangular Rapid Flashing Beacon, Remove Complete Sign Assembly As 1.000 0654- 3- 10 Midblock Crosswalk: Pedestrian Hybrid Beacon Assembly, Furnish & Install Complete Assembly As 1.000 0660- 1-101 Loop Detector Inductive, f&i, Type 1 Ea 1.000 0660- 1-102 Loop Detector Inductive, f&i, Type 2 Ea 1.000 0660- 1-109 Loop Detector Inductive, f&i, Type 9 Ea 1.000 0660- 1-110 Loop Detector Inductive, f&i, Type 10 Ea 5.000 0660- 2-102 Loop Assembly, f&i, Type b As 100.000 0660- 2-103 Loop Assembly, f&i, Type c As 1.000 0660- 2-106 Loop Assembly, f&i, Type f As 100.000 0660- 3- 11 Vehicle Detection System- Microwave, Furnish & Install Cabinet Equipment Ea 1.000 0660- 3- 12 Vehicle Detection System- Microwave, Furnish & Install, Above Ground Equipment Ea 1.000 0660- 4- 11 Vehicle Detection System- Video, Furnish & Install Cabinet Equipment Ea 1.000 0660- 4- 12 Vehicle Detection System- Video, Furnish & Install Above Ground Equipment Ea 1.000 0660- 4- 60 Vehicle Detection System- Video, Remove Ea 1.000 0660- 6-421 Vehicle Detection System- Avi, Bluetooth Relocate, Cabinet Equipment Ea 1.000 0660- 6-422 Vehicle Detection System- Avi, Bluetooth Relocate, Above Ground Equipment Ea 1.000 0663- 1-111 Signal Priority And Preemption System, f&i, Optical, Cabinet Electronics Ea 1.000 0663- 1-400 Signal Priority & Preemption System, Relocate Ea 1.000 0665- 1- 11 Pedestrian Detector, Furnish & Install, Standard Ea 100.000 0665- 1- 12 Pedestrian Detector, Furnish & Install, Accessible Ea 20.000 0665- 1- 40 Pedestrian Detector, Relocate Ea 1.000 0665- 1- 60 Pedestrian Detector, Remove- Pole/Pedestal To Remain Ea 1.000 0670- 4- 1 Intersection Control Beacon Controller Assembly, Furnish & Install As 1.000 0670- 5-110 Traffic Controller Assembly, f&i, Nema As 6.000 0670- 5-111 Traffic Controller Assembly, f&i, Nema, 1 Preemption As 1.000 0670- 5-112 Traffic Controller Assembly, f&i, Nema, 2 Preemption As 1.000 0670- 5-400 Traffic Controller Assembly, Modify As 6.000 0670- 5-500 Traffic Controller Assembly, Relocate Controller With Cabinet As 1.000 0670- 5-600 Traffic Controller Assembly, Remove Controller With Cabinet As 1.000 0676- 1-113 Traffic Signal Controller Cabinet, Furnish & Install Cabinet Without Controller, Nema Type/Size 3, 24" w x 40" h x 15" d Ea 1.000 0676- 1-116 Traffic Signal Controller Cabinet, Furnish & Install Without Controller, Nema Size6, 44" w x 52" h x 24" d Ea 1.000 0676- 1-135 Traffic Signal Controller Cabinet, Furnish & Install w/Out Controller, Nema Unwired Size 5, 30" w x 48" h x 16" d Ea 1.000 0676- 1-600 Traffic Signal Controller Cabinet, Remove Ea 1.000 Section 0006 Intelligent Transportation System 0630- 2- 11 Conduit, Furnish & Install, Open Trench Lf 700.000 0630- 2- 12 Conduit, Furnish & Install, Directional Bore Lf 16,000.000 0630- 2- 14 Conduit, Furnish & Install, Aboveground Lf 100.000 0633- 1-121 Fiber Optic Cable, f&i, Underground,2-12 Fibers Lf 600.000 0633- 1-122 Fiber Optic Cable, f&i, Underground,13-48 Fibers Lf 1,500.000 0633- 1-123 Fiber Optic Cable, f&i, Underground,49-96 Fibers Lf 2,000.000 0633- 1-620 Fiber Optic Cable, Remove, Underground Lf 250.000 0633- 2- 31 Fiber Optic Connection, Install, Splice Ea 70.000 0633- 2- 32 Fiber Optic Connection, Install, Termination Ea 50.000 0633- 3- 11 Fiber Optic Connection Hardware, f&i, Splice Enclosure Ea 4.000 0633- 3- 12 Fiber Optic Connection Hardware, f&i, Splice Tray Ea 7.000 0633- 3- 13 Fiber Optic Connection Hardware, f&i, Preterminated Connector Assembly Ea 3.000 0633- 3- 14 Fiber Optic Connection Hardware, f&i, Buffer Tube Fan Out Kit Ea 3.000 0633- 3- 15 Fiber Optic Connection Hardware, f&i, Preterminated Patch Panel Ea 1.000 0633- 3- 16 Fiber Optic Connection Hardware, f&i, Patch Panel- Field Terminated Ea 2.000 0633- 3- 17 Fiber Optic Connection Hardware, f&i, Connector Panel Ea 1.000 0635- 2- 11 Pull & Splice Box, f&i, 13" x 24" Cover Size Ea 200.000 0635- 2- 12 Pull & Splice Box, f&i, 24" x 36" Cover Size Ea 10.000 0639- 1-113 Electrical Power Service, f&i, Overhead Meter Not Required As 1.000 0639- 3- 11 Electrical Service Disconnect, f&i, Pole Mount Ea 1.000 0676- 2-111 Its Cabinet, Furnish & Install, Pole Mount, 336, 24" w x 36" h x 20" d Ea 1.000 0676- 2-122 Its Cabinet, Furnish & Install, Pole Mount With Sunshield, 336s, 24" w x 46" h x 22" d Ea 1.000 0676- 2-132 Its Cabinet, Furnish & Install, Base Mount, 336s, 24" w x 46" h x 22" d Ea 1.000 0676- 2-143 Its Cabinet, Furnish & Install, Base Mount, 334, 24" w x 66" h x 30" d Ea 1.000 0676- 3- 10 Small Equipment Enclosure, Furnish And Install, Less Than 10"w x 13"h x 11" d Ea 1.000 0678- 1-112 Controller Accessories, Replace Existing- Furnish And Instal, Master Clock Unit Ea 1.000 0682- 1-113 Its Cctv Camera, f&i, Dome Ptz Enclosure - Pressurized, Ip, High Definition Ea 2.000 0682- 1-133 Its Cctv Camera, f&i, Dome Enclosure - Non-Pressurized, Ip, High Definition Ea 2.000 0682- 1-400 Its Cctv Camera, Relocate Ea 1.000 0682- 1-600 Its Cctv Camera, Remove & Disposal Ea 1.000 0682- 2- 40 Video Display Equipment, Relocate Ea 1.000 0684- 1- 1 Managed Field Ethernet Switch, Furnish & Install Ea 1.000 0684- 1- 4 Managed Field Ethernet Switch, Relocate Ea 1.000 0684- 1- 6 Managed Field Ethernet Switch, Remove- Cabinet To Remain Ea 1.000 0684- 2- 1 Device Server, Furnish & Install Ea 2.000 0684- 2- 4 Device Server, Relocate Ea 1.000 0684- 5- 1 Media Converter, Furnish & Install Ea 1.000 0684- 6- 11 Wireless Communication Device, Furnish & Install Ethernet Access Point Ea 1.000 0684- 6- 60 Wireless Communication Device, Remove Ea 1.000 0685- 1- 11 Uninterruptible Power Supply, Furnish And Install, Line Interactive Ea 1.000 0685- 1- 12 Uninterruptible Power Supply, Furnish And Install, Online/Double Conversion Ea 6.000 0685- 1- 13 Uninterruptible Power Supply, Furnish And Install, Line Interactive With Cabinet Ea 6.000 0685- 1- 14 Uninterruptible Power Supply, Furnish And Install, Online/Double Conversion With Cabinet Ea 1.000 |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |