Similar Projects
HVAC and Electrical Services
Term Contract
Post-Bid

20 Ton Indoor Handler Unit
Post-Bid
Columbia, SC

HVAC Maintenance and Repair Services
Term Contract
Results
Columbia, SC

Energy Savings Performance Services
Term Contract
Results
Columbia, Eastover, Hopkins, SC 29209

Make Up Air Unit
Post-Bid
Columbia, SC 29210

Tucker Center Chiller Replacement Project
Results
$700,000 to $922,000 est. value
Columbia, SC 29203

Sims/Aycock Building - Replace Control Valves
Post-Bid
$45,000 to $55,000 est. value
Columbia, SC 29201

J--Air Handler Filter Service
Results
Columbia, SC 29209

SC DMH Midlands Center Multizone HVAC Unit Replacement
Post-Bid
$200,000 to $240,000 est. value
Columbia, SC 29203

Monitoring and Controls of Two (2) Air Handling Units
Results
Columbia, SC 29201

Purchase of CTB Chiller and Compressor
Post-Bid
Columbia, SC 29202

McAdams Hall Duct Cleaning
Results
Less than $19,440 est. value
Columbia, SC

Roofing/HVAC Replacement - Richland Northeast High School
Post-Bid
Columbia, SC 29223

USC School of Medicine Med Park 15 - Replace AHU-1 and 2
Results
$120,000 to $140,000 est. value
Columbia, SC

HVAC Maintenance and Repair Services
Term Contract
Post-Bid
Columbia, SC 29204

Last Updated 03/23/2021 12:54 PM
Project Title

Annual Chiller Maintenance

Physical Address View project details and contacts
City, State (County) Columbia, SC 29201   (Richland County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Provision and installation of new oil filter, purge filter, refrigerant filter • Full inspection of controls, safeties, starter, and purge systems, per manufacturer’s guidelines including at least the following. Each of the items listed should be included in a detailed Service Report. The Service Report will also notate any abnormal conditions or measurements: o Review diagnostics o Check for oil leaks o Check oil temperature o Take an oil analysis per circuit o Lock out tag out units with potentially high or medium voltage o Vane linkage and lubricate valves o Carry out compressor starter inspection o Carry out control panel electrical inspection o Carry out low temperatures’ sensor calibration o Drain rupture disc vent line if a drain is located on the line o Remove lock out tag out and restore power for units with medium or high voltage starters o Carry out a pre-start chiller check o To restart chiller • Removal and disposal of all trash, debris, and oil from job sites when job is completed for the day • Off-site disposal of used parts, debris, and/or trash • Reporting of any observed equipment deficiencies to the main contact the same day they are observed • Drafting and provision of an oil analysis report as well as a detailed Service Report per chiller. The Contractor shall use a third-party certified laboratory to perform oil analyses. Oil analysis will include, at a minimum, moisture, acid, tin, zinc and wear metal data.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts