Similar Projects
Fire Suppression System Inspection and Repair
Term Contract
Results
Orlando, FL 32801

Fire Suppression System
Post-Bid
$100,000 to $199,999 est. value
Orlando, FL 32801

Fire Alarm System Services
Term Contract
Results
FL

Multiple Sites Low Voltage Systems Capital Renewal Project
Results
Less than $20,700,000 est. value
Orlando, FL 32809

Fire Suppression Systems - Testing, Inspection, and Maintenance
Alteration
Bidding
Orlando, FL 32805

Administrative Services Fire Alarm System Replacement
Results
$611,400 est. value
Orlando, FL 32801

Regional History Center Building Automation System (Bas), Fire Alarm, And Smoke Controls Replacement
Alteration
Results
$727,000 est. value
Orlando, FL 32801

Maintenance, Monitoring, Testing and Inspections of Fire Alarm, Access and Security Systems
Term Contract
Results
Less than $450,000 est. value
Alachua, Daytona Beach, Fort Lauderdale, Fort Myers, Fort Pierce, Jacksonville, Lakeland, Largo, Marathon, Miami, Opa-locka, Orlando, Pensacola, Saint Petersburg, Tallahassee, Tampa, West Palm Beach, FL

Fire Extinguisher Purchase, Inspection and Repairs
Alteration
Results
Orlando, FL

J012--FY22 - Fire Alarm Monitoring ONYX
Term Contract
Post-Bid
Orlando, FL 32827

Fire Alarm System Testing, Certification and Repair OIA
Alteration
Post-Bid
Orlando, FL

Fire Extinguisher and Commercial Kitchen Hood Inspection, Maintenance, and Repair Service
Alteration
Post-Bid
Orlando, FL

Central Fire Alarm Monitoring Services
Results
FL

Pershing Fire Pump Replacement
Results
Orlando, FL

Commercial Plumbing Service and Fire Sprinkler Repair and Parts Services
Alteration
Post-Bid
Orlando, FL

Last Updated 12/06/2021 05:15 AM
Project Title

Convention Center Campus Dry Sprinkler Pipe Replacement

Physical Address View project details and contacts
City, State (County) Orlando, FL 32819   (Orange County)
Category(s) Single Trades
Sub-Category(s) Fire Protection
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $15,281,360
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Replace end of life equipment of Dry Sprinkler Pipe Systems. These systems are corroded on the inside and exhibiting pin hole leaks which drops the air pressure (psi) below 50 psi inside the dry sprinkler pipes and triggers the system to release the water into the sprinkler pipes. This situation causes and automatic "Water Flow" alarm and activates a full building fire alarm evacuation. The random pin-hole air leaks can cause unannounced evacuation of the West or North-South buildings at any time and makes the operation of the building for the event /show /conference an unpredictable event. Dry Pipe Replacement Project will replace the Dry Sprinkler System at the West Building, North-South Building and the Connector Pedestrian Bridge, to improve the reliability of the system. the removal and replacement of the exterior ceilings as required to execute the dry pipe sprinkler system replacement.

Details

Division 21 - Fire Suppression.
Division 28 - Electronic Safety and Security, Fire Detection and Alarm.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents