Similar Projects
Repair CHPP Electrical Panels & Circuits Phase B
Term Contract
Bidding
$1,000,000 to $5,000,000 est. value
Eielson AFB, AK

Borough and Maintenance Buildings Mechanical Upgrade
Alteration
Post-Bid
Kodiak, AK 99615

Port Of Alaska Utility Locates
Alteration
Post-Bid
Less than $50,000 est. value
Anchorage, AK

Port of Alaska Rectifier Refurbishment
Alteration
Results
$1 to $500,000 est. value
Anchorage, AK

West High School Pool Lighting Upgrades
Alteration
Post-Bid
$1 to $100,000 est. value
Anchorage, AK 99509

Carlson Center Lighting Upgrade
Alteration
Results
$10,000 to $100,000 est. value
Fairbanks, AK 99701

Proposed Solar Project On Kenai Peninsula Would Be Alaska'S Largest
Infrastructure
Pending Verification
$30,000,000 est. value
Kenai, AK

Generator Removal Station Five-One
Alteration
Post-Bid
Palmer, AK 99645

Reported 02/05/2022 12:00 AM
Project Title

Nonpersonal Services to Provide Full Electrical Functionality

Physical Address View project details and contacts
City, State (County) Metlakatla, AK 99926   (Prince of Wales-Outer Ketchika County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Accepting Letters of Interest
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Specific project tasks, to provide full electrical functionality to the H2 conex, that are anticipated by the government include: ? Site Assessment ? Lockout/Tagout (120V/240V system) ? Check site electrical panel for serviceability ? Check site lighting junction boxes for serviceability ? Check Grounding & Continuity (conex, stairs, fence) ? Ground & bond conex, stair, and fence systems ? Ground & bond autosonde system ? Pull/install wire ? Bond interior bus bar using the conex circuit ? Label main disconnect breaker (on schedule & breaker) ? Check interior electrical panel for serviceability ? Install exterior door light ? Install exterior hydrogen conex disconnect ? Check exterior receptacle for serviceability ? Ensure that all H2 conex electrical circuits are functioning and meet code ? Install missing weather heads for wire ? Document work via photos & sketch/drawing

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents