Similar Projects
B2032 Repair HVAC Systems
Infrastructure
Design
$500,000 to $1,000,000 est. value
Quantico, VA

Waterfield Bldg. Ceiling Modernization Project
Infrastructure
Design
$1,000,000 to $5,000,000 est. value
Norfolk, VA

Courthouse HVAC Upgrade
Term Contract
Bidding
Bland, VA 24315

HVAC Renovations at Francis Hammond Intermidiate School
Alteration
Bidding
Alexandria, VA 22304

HVAC Maintenance and Repairs for the Aquatics Center
Term Contract
Post-Bid
Christiansburg, VA

W--Tent and A/C Unit Rental
Post-Bid
Fort Myer, VA 22211

Roof Top Air Handling Unit
Results
Chesapeake, VA 23323

Fire Station 206 HVAC Upgrade
Results
Alexandria, VA 22304

Cooling Tower Replacement at Henrico Training Center
Alteration
Bidding
Richmond, VA 23228

HVAC Preventative Maintenance and On Call / Multiple Locations
Term Contract
Post-Bid
Appomattox, Chesterfield, Glen Allen, Salem, Wytheville, VA 23235

Round Elementary HVAC/BAS Replacement
Results
$1,489,000 to $1,518,780 est. value
Manassas, VA 20108

CATEC Kitchen MEP Upgrades
Alteration
Bidding
Charlottesville, VA 22901

Preventative Maintenance and Repair Services for Compressed Breathing Air Systems
Term Contract
Post-Bid
VA

CSS 17592 - Replace 250 Gallon Air Compressor, Fort Eustis (VA056)
Results
Fort Eustis, VA

CTE Heating System Renovations at the Pulaski County High School CTE Center
Alteration
Bidding
Dublin, VA 24084

Reported 12/14/2021 12:00 AM
Project Title

Freedom Aquatic and Fitness Center Replacement of Natatorium Units

Physical Address View project details and contacts
City, State (County) Manassas, VA 20110   (Prince William County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

1. Provide an extension to the owners existing Siemens Building Automation System (BAS) 2. Provide labor to make safe existing control wiring to AHU 4, 5, & 6. 3. Provide labor and material to connect AHU 5 & 6 to existing Siemens BAS a. Units shall be shipped with factory provided and installed controls required to meet sequence of operation. b. Siemens will provide hardwired points to be terminated on factory provided and wired terminal strip. c. Monitoring and control points displayed on the BAS shall be limited to the following: supply temp, return temp, room temp, room humidity, On/Off control, and status. d. Provide field wiring to install sensors shipped loose with AHU. Existing wiring shall be reused where possible. e. Mount and wire operators display provided by others. 120V power for panel shall be provided by others. f. Provide interlock wiring between AHU and CU g. Reuse or expand existing Siemens PXCM panels to meet sequence of operations 4. Provide labor and material to connect AHU 4 to existing Siemens BAS a. Provide field installation of new DDC controls in accordance with M701. b. Provide new PXC panel or TX-I/O expansion on existing PXCM panel. If new PXC panel is required, GMU will provide network drop for new panel. c. Provide (1) new Siemens room temperature and humidity thermostat to be installed in existing thermostat location. Existing wiring pathway shall be reused. d. Provide immersion temperature sensor for hot water temperature monitoring. Furnish well for installation by others. e. Outdoor, defrost control, and backdraft dampers provided by unit manufacture f. Furnish (2) control valves for installation by others.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents