Similar Projects
Last Updated | 12/05/2022 07:48 PM |
Project Title | North Water Pollution Control Facility (NWPCF) Operations and Maintanance Building and Seaside Park Pump Station CPS-3 Generator Replacements |
Physical Address | View project details and contacts |
City, State (County) | Brick, NJ 08723 (Ocean County) |
Category(s) | Sewer and Water |
Sub-Category(s) | Lift and Pump Stations, Sewage Treatment Plant |
Contracting Method | Competitive Bids |
Project Status | Contract Award, Construction start expected December 2022 |
Bids Due | View project details and contacts |
Estimated Value | $770,316 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | **As of November 28, 2022, this project has not yet been awarded. The project is expected to be awarded on December 5, 2022.** The site is located at 255 Mantoloking Road, Brick, NJ 08723 and 1214 Barnegat Ave, Seaside Park, NJ 08753. Project Description - Contract No. ND2007, the Work, includes but is not necessarily limited to the replacement of the existing 75kW emergency diesel generator for the NWPCEF Operations and Maintenance Building with a new 250kW diesel generator, including a 1470-gallon diesel base tank and new ATS. The Work also includes the replacement of the existing 155kW emergency diesel generator located inside Seaside Park Pump Station CPS-3 with a new 175kW generator to be located outside the pump station on an existing concrete platform currently used for the Convault diesel tank that is to be removed. The new 175kW generator will include a 1055-gallon diesel base tank and a raised access platform and stairs. The Work is located within the North Water Pollution Control Facility (NWPCF) in Brick Township and at CPS-3 in the Borough of Seaside Park, New Jersey. The site is located at 255 Mantoloking Road, Brick, NJ 08723 and 1214 Barnegat Ave, Seaside Park, NJ 08753. Cash or credit cards are not accepted. If a check is mailed, please direct it to the attention of the Engineering and Construction Department. Provide the name of the individual at the firm that 1s requesting the Bidding Documents to whom all correspondence generated during the bid period may be addressed (i.e. Item No. 6 below). Bidding Documents will be shipped only if the requesting party includes their overnight shipping service number. Bid Security - In accordance with N.J.S.A. 40A:11-21, each Bid shall enclose Bid Security, as specified in the Instructions to Bidders, in the amount of ten percent (10%) of the Bidder's Bid, but not in excess of $20,000. Please copy the Engineering and Construction Department Contract Administrator Linda Salussolia (lsalussolia@ocua.com) on any e-mails or correspondence you may send to the Project Engineer or the Authority. The Authority is doing everything within its capabilities to protect employees' health, safety and welfare, while at the same time continuing to provide the level of services expected by our participants. We are committed to ensuring the workplace is safe and healthy for all employees. |
||||||||||||||||||||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |