Similar Projects
Lexington Terrance Termite Repairs
Alteration
Bidding
$200,000 est. value
Pensacola, FL 32507

Escambia County CRA Income-Based Roof Program Solicitation - Round 8
Alteration
Post-Bid
Pensacola, FL 32505

Escambia County CRA Income-Based Roof Program Solicitation
Alteration
Post-Bid
Cantonment, Pensacola, FL 32501

C.A. Weis Elementary Roof Replacement
Results
Less than $3,018,900 est. value
Pensacola, FL 32505

Escambia County CRA Income-Based Roof Program Solicitation - Round 6
Results
Cantonment, Pensacola, FL 32505

Escambia County CRA Income-Based Roof and Hurricane Loss Mitigation Program
Alteration
Post-Bid
FL

District-Wide Roof Maintenance, Repair, and Replacement
Alteration
Results
FL

Century Correctional Institution and Pensacola WRC Roof Repairs
Alteration
Post-Bid
$700,000 est. value
Century, FL 32535

Roof Repair for the Road Prison Fish House/K9 Building
Alteration
Results
Cantonment, FL 32533

Roof Repair / Replacement at Palm Lake Village Apartments
Alteration
Post-Bid
Dunedin, FL 34698

Roof Repair for Road Prison AC Filter/Storage Shed
Alteration
Results
Cantonment, FL 32533

Escambia County CRA Income - Based Roof Program and HLMP
Alteration
Post-Bid
Pensacola, FL 32506

Roof Repair for Road Prison Classroom
Alteration
Results
Cantonment, FL 32533

Century Courthouse Roof Replacement
Alteration
Post-Bid
Century, FL 32535

Roof Repair for Prison RCO Maintenance Office
Alteration
Results
Cantonment, FL 32533

Last Updated 07/20/2022 05:47 PM
Project Title

Roof Repair for Road Prison Paint Shed

Physical Address View project details and contacts
City, State (County) Cantonment, FL 32533   (Escambia County)
Category(s) Single Trades
Sub-Category(s) Roofing
Contracting Method Competitive Bids.
Project Status Results,
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

1. Proper staging of materials. Materials shall arrive onsite in their manufacturers labeling and be kept in a watertight/temperature safe environment prior to installation as per all manufacturers’ recommendations that apply. 2. Remove 200 SF of existing asphaltic 3-tab shingles and underlayment components down to the lumber decking. 50 LF of edge metal components and 25 LF of ridge vent should also be removed and properly disposed of. 3. Once the existing roof system has been removed the lumber decking should be assessed for adverse moisture damages. Any damaged lumber should be removed and replaced with like kind and quality components. In addition to the lump sum bid, the contractor should include a unit price for lumber to accommodate for unforeseen deck conditions. 4. New synthetic underlayment (200 SF) should then be installed atop the lumber deck per manufacturer recommendations. Ensure the underlayment is positively lapped to prevent water bucking. 5. Install 50 LF of new aluminum edge metal along all rake lines and eaves. The underlayment should transition atop the edge metal at the eave or be stripped in with self-adhered membrane or roofing cement. 6. Install 200 SF of new architectural laminate shingles (aesthetics to be approved by owner) per manufacturer recommendations. Ensure fastener attachment patterns are adequate for uplift requirements (6 fasteners recommended). 7. Install 25 LF of new ridge vent per manufacturer recommendations. Ensure ridge shingles are blind nailed as required by the manufacturer.

Details

Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents