Similar Projects
Draft: Repair Roof and HVAC System at Main CDC Bldg. 2530
Term Contract
Design
San Antonio, TX

Hvac Maintenance and Repair Including Quarterly Inspections and Seasonal Preventative Maintenance
Alteration
Bidding
San Antonio, TX

HVAC Disposable Air Filters for San Antonio Airport System
Post-Bid
San Antonio, TX 78283

HVAC Cleaning - JBSA RAN Bldg 693
Post-Bid
Universal City, TX 78150

Maintenance Building Rooftop Air Heater Replacement
Results
Less than $790,000 est. value
San Antonio, TX 78212

Closed Circuit Cooling Tower Replacement
Results
San Antonio, TX

Air Handling Units Replacement
Post-Bid
San Antonio, TX 78221

Specialized Air Conditioning Maintenance and Repair for IT Spaces (ITSD)
Results
Less than $228,700 est. value
San Antonio, TX 78200

A/C for Central Utility Plant Preventive Maintenance and Repairs
Post-Bid
San Antonio, TX 78216

Chimney, Vent, and Duct Cleaning Services Agency Wide
Results
Less than $262,000 est. value
San Antonio, TX 78204

HVAC Repair Multiple-Award Blanket Purchase Agreement
Post-Bid
San Antonio, TX

Chiller Maintenance and Compressor Replacement
Results
San Antonio, TX

HVAC Maintenance Contract
Post-Bid
San Antonio, TX 78230

IAAFA HVAC BLDGS 7353;7355;7358
Results
$500,000 to $1,000,000 est. value
San Antonio, TX 78236

Lighting, Mechanical and Fire Alarm Upgrades at Various Campuses
Post-Bid
Less than $397,000 est. value
San Antonio, TX 78250

Last Updated 12/15/2021 11:18 PM
Project Title

2022 Chiller Replacement at Wilson Elementary School

Physical Address View project details and contacts
City, State (County) San Antonio, TX 78201   (Bexar County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $567,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

A. Remove and replace existing chilled water central plant equipment and piping to include air-cooled chillers, chilled water pumps, expansion tank, air separator, filter feeder, associated controls and associated outdoor and mechanical room indoor above-ground piping. B. Provide chilled water piping provisions for emergency chiller connection. C. Provide access for crane/rigging equipment to remove and install chillers. D. Electric heat tracing of outdoor chilled water piping. E. New chiller equipment concrete pad and new column pipe stands for outdoor piping and conduits. F. Testing, adjusting and balancing of new chillers and chilled water pumps. G. VFDs for new chilled water pumps. H. Replace electrical circuitry for connection to new chillers and pumps. I. Add electrical power for new electric heat tracing and new controls. J. Provide new chiller plant power meter. K. Commissioning of new chillers, chilled water pumps, piping, and associated electrical circuitry. The estimated construction budget is $567,000 which includes a $27,000 contingency.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents