Similar Projects
Last Updated | 10/07/2022 02:38 AM |
Project Title | Cypress Branch Pellet Furnace |
Physical Address | View project details and contacts |
City, State (County) | Millington, MD 21651 (Kent County) |
Category(s) | Entertainment/Recreation |
Sub-Category(s) | Misc. Recreational |
Contracting Method | Competitive Bids |
Project Status | Bidding, Construction start expected December 2022 |
Bids Due | View project details and contacts |
Estimated Value | $148,691 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Cypress Branch Pellet Furnace If you have any questions, please email or call the Project Manager Ramiz Alobaidi 443-454-8867 ramiz.alobaidi@maryland.gov or Procurement Officer Shenika Jackson 410-260-8903 shenika.jackson2@maryland.gov. Should you require any help with eMMA, please email the eMMA Helpdesk at emma.hepdesk@maryland.gov. To have contractor to provide all labor, equipment, materials, supplies, insurance, etc necessary to properly install a wood pellet boiler system in the Wick Shop Building, located at 10701 Galena Road, Millington, Kent Count, MD 21651. If the project requires any specific type of license, please put the license number(s) on the Bid Form attachment. Please upload your bid response documents as one attachment. We strongly suggest attending the pre-bid meeting. The job completion time is 90days and $250 per day for liquidated damages. SCOPE: 1. This project consists of the Contractor providing all labor, equipment, materials, supplies, insurance, etc., necessary to properly install a wood pellet boiler system in the Wick Shop Building, located at 10701 Galena Road, Millington, Maryland, MD 21651. 2. The proposed project shall include but is not limited to the following: a. Design, build, and install a 50,000 Btu/hr biomass combustion boiler system that utilized wood pellets as fuel coupled with thermal storage, hydronic components, and a biomass storage and conveyance system. System must be capable of properly heating Zone 4 and 5 of the Shop Building. See attached USDA Draft Memorandum |
||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |