Reported | 10/20/2021 03:38 PM |
Project Title | Photonic Laser Install |
Physical Address | View project details and contacts |
City, State (County) | San Antonio, TX 78275 (Bexar County) |
Category(s) | Government/Public |
Sub-Category(s) | Military Facility |
Contracting Method | |
Project Status | Abandoned |
Bids Due | View project details and contacts |
Estimated Value | $500,000 to $1,000,000 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The contractor shall provide design and construction services to modify R6103 B3260 at JBSA - Ft Sam Houston for the installation of an IPG Photonic Laser Model YLS-50000.2lll. The Contractor shall modify R6103 as follows: seal existing 4" communication conduit into anechoic chamber. Bore and install an 8" PVC communication conduit in location specified by 711 HPW/OMT. provide an area covering the back right corner of the anechoic chamber (looking in from the door) that extends 3-ft on each side of the corner and a second section that covers 4 linear feet that can slide to any position along the 20-ft wall of the chamber, with the bottom resting on/supported by floor. provide Fine Grain Extruded Graphite plates, Grade GR060, by Graphtec LLC (or equal; comparable grades are CBY or G11). Plates to be 1" thick by 12" wide by 72" long/tall. Install plate`s vertical (12" wide by 72" tall), 3 plates on left side of corner and 7 plates on the right side. Manufacture a frame to hold the panels that allows the ability to slide graphite plates right/left for future removal and replacement as necessary. Verify location with 802d CES project manager prior to securing. provide cement backer board on the interior anechoic chamber walls (except on ceiling).Replace any ceiling tiles affected by work completed within scope. Match existing ceiling tiles in the room. Install Government provided IPG Photonics remote Air/Water model LC 340.01-A.3.6, 460V, 60Hz along exterior of facility. construct a chiller pad enclosure 4" concrete equipment pad, 3000 psi minimum, along south wall of facility where the enclosure shall be constructed of cinder block with a brick veneer finish to match existing. See concept drawings shown as attachments. install chillers on pad as per manufacturer`s specifications. Refer to manufacturer`s Pre-Installation Guide and Operating Manual (attached to the SOW). provide netting at the top of the chiller enclosure preventing birds from netting and anti-rodent solution to prevent infestation. |
||||||||||||||||||||||||||||||
Details | Military Facility, Renovation.
|
||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||
Project Documents |
![]() Engineered Spec Sheet ![]() Architectural Plans ![]() Other Documents |