Similar Projects
Elevator Modernization
Renovation
Sub-Bidding
$841,000 CJ est. value
Nelsonville, OH 45764

Faculty Club Elevator Replacement
Renovation
Sub-Bidding
$512,300 CJ est. value
Columbus, OH 43210

Town Hall Elevator Modernization and Elevator Maintenance Recreation Center and Administrative Building
Alteration
Post-Bid
Groveport, OH 43125

FILA - Elevator Service
Term Contract
Post-Bid
Canton, OH 44702

Akron Replace Judges-Prisoners Elevator
Alteration
Results
Akron, OH 44308

Elevator Safety Repairs and Replacements
Renovation
Results
$675,000 est. value
Youngstown, OH 44502

1201 Lakeside Avenue Elevators Replacement
Renovation
Sub-Bidding
$200,000 CJ est. value
Cleveland, OH 44114

Woodland Data Center Freight Elevator Project
Alteration
Post-Bid
Cleveland, OH 44104

Elevator Service Agreement
Alteration
Results
Jefferson, OH 44047

Pleasant Hill Lake Park - Area A Lift Station Generator
Renovation
Sub-Bidding
$129,200 CJ est. value
Perrysville, OH 44864

Elevator Maintenance Services
Term Contract
Post-Bid
Columbus, Dayton, OH 43215

Elevator Maintenance and Repair Services
Alteration
Results
$300,000 est. value
Cincinnati, OH

Full-Service Elevator and Escalator Mechanical Services
Term Contract
Sub-Bidding
Columbus, OH 43215

Elevator Maintenance Services
Term Contract
Post-Bid
Springfield, OH 45503

Elevator Maintenance
Term Contract, Alteration
Results
$62,878 est. value
OH

Last Updated 04/03/2023 09:13 AM
Project Title

Hydraulic Passenger Elevator Modernization

Physical Address View project details and contacts
City, State (County) Cincinnati, OH 45223   (Hamilton County)
Category(s) Single Trades
Sub-Category(s) Conveying Systems
Contracting Method Competitive Bids
Project Status Contract Award, Construction start expected April 2023
Bids Due View project details and contacts
Estimated Value $173,900 [brand] Estimate
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Submit all questions regarding this RFP in writing to anthony.cowden@cincinnatistate.edu by Thursday February, 23 no later than 2:00 pm with the project name included in the subject line. Questions will be answered and posted on the College website prior to the response date. The following required building work has been identified by the State of Ohio elevator inspector during the site visit on January 18, 2023: Machine Room o Install a new 110V disconnect with pipe and wire connection to the new elevator controller to supply the dedicated service for cab lighting. o Install additional machine room lighting, at a minimum one (1) additional 4-foot light fixture, located to illuminate the new elevator controller. o Install new GFCI duplex outlet on a dedicated circuit. o Install a new smoke and heat detector as required to interface with the building fire alarm system. o install the required elevator emergency fire service interface control, including three (3) new contacts. (Fire Service Phase I, Fire Service Phase II, Machine Room detector) o Install HVAC climate control in the machine room (mini-split system, etc.) to provide temperature control for the room in accordance with the requirements of the new elevator control equipment. o Remove, enclose, or install a drain pain under the existing building drain pipes that are located within the machine room. Elevator Pit o Furnish and install a new GFCI duplex outlet, 4' light fixture, and light switch on dedicated circuits as required. o Furnish and install a dedicated circuit for a new surface mount sump pump. To be verified once the elevator is raised to provide pit access. o Furnish and install a surface mount sump pump with pipe routed to a location as confirmed by the Building Owner. To be verified once the elevator is raised to provide pit access. Elevator Hoistway o Install new heat and smoke detectors at the top of the hoistway. Elevator Lobby o Interface the existing Lobby smoke detectors at all floors to the existing building fire protections system as required to operate with the new elevator Emergency Fire Service Operation. o Please note that there is a tall ceiling height at the upper floor, that elevates the existing smoke detector to a considerable distance from the elevator entrance. The Inspector advised that further investigation was required to verify that the height of this smoke detector was following current code requirements. This issue will require a follow-up verification from elevator inspection authority. This summary of building related work has been identified by the State Inspector, John Beckman. A disclaimer was provided that the final building related scope of work would be reviewed and confirmed by the elevator inspection supervisor, and that the inspection authority reserved the right to modify this scope as necessary. Please contact me if you have any questions.

Details

Division 14 - Conveying Equipment, Operation and Maintenance of Conveying Equipment, Common Work Results for Conveying Equipment, Commissioning of Conveying Equipment, Elevators, Escalators and Moving Walks, Escalators.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents