Similar Projects
Last Updated | 06/15/2020 02:48 AM |
Project Title | Sign Repair |
Physical Address | View project details and contacts |
City, State (County) | (Bay, Calhoun, Escambia, Franklin, Gadsden, Gulf, Holmes, Jackson, Jefferson, Leon, Liberty, Okaloosa, Santa Rosa, Wakulla, Walton, Washington Counties) |
Category(s) | Heavy and Highway |
Sub-Category(s) | Highway Signs/Guardrails/Barriers |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The purpose of this Contract is to provide Sign Repair and Replacement Operations pursuant to a Governor and/or President Declaration of a State Emergency. This Contract will be a regional contract that includes counties within District Three. The Contractor shall perform Sign Repair and Replacement Operations pursuant to the terms of this Contract and at the direction of the Department. Section 0001 Emer.Delineator/Attenuator/Sign Repr(Ea) 0630- 2- 11 Conduit, Furnish & Install, Open Trench Lf 500.000 0630- 2- 12 Conduit, Furnish & Install, Directional Bore Lf 500.000 0630- 2- 14 Conduit, Furnish & Install, Aboveground Lf 1,000.000 0630- 2- 15 Conduit, Furnish & Install, Bridge Mount Lf 1,000.000 0632- 7- 2 Signal Cable- Repair/Replace/Other, Furnish & Install Lf 1,000.000 0634- 4-142 Span Wire Assembly, f&i, Single Point, Diagonal Pi 40.000 0634- 4-152 Span Wire Assembly, f&i, Two Point, Diagonal Pi 40.000 0635- 2- 11 Pull & Splice Box, f&i, 13" x 24" Cover Size Ea 20.000 0635- 2- 12 Pull & Splice Box, f&i, 24" x 36" Cover Size Ea 20.000 0639- 1-111 Electrical Power Service, f&i, Overhead, Meter Furnished By Power Company As 5.000 0639- 1-112 Electrical Power Service, f&i, Overhead Meter Purchased By Contractor From Power Company As 5.000 0639- 1-113 Electrical Power Service, f&i, Overhead Meter Not Required As 5.000 0639- 1-121 Electrical Power Service, f&i, Underground, Meter Furnished By Power Company As 5.000 0639- 1-122 Electrical Power Service, f&i, Underground, Meter Purchased By Contractor As 5.000 0639- 1-123 Electrical Power Service, f&i, Underground, Meter Not Requiredas 5.000 0641- 2- 12 Prestressed Concrete Pole, f&i, Type p-Ii Service Pole Ea 10.000 0641- 2- 15 Prestressed Concrete Pole, f&i, Type p-v Ea 10.000 0670- 4- 1 Intersection Control Beacon Controller Assembly, Furnish & Install As 20.000 0700- 1- 11 Single Post Sign, f&i Ground Mount, Up To 12 Sf As 400.000 0700- 1- 12 Single Post Sign, f&i Ground Mount, 12-20 Sf As 600.000 0700- 1- 13 Single Post Sign, f&i Ground Mount, 21-30 Sf As 200.000 0700- 1- 14 Single Post Sign, f&i Ground Mount, 31+ Sf As 100.000 0700- 1- 21 Single Post Sign, f&i Barrier Mount Index 11871/700-013 Up To 12 Sf As 200.000 0700- 1- 22 Single Post Sign, f&i Barrier Mount Index 11871/700-013, 12-20 Sf As 100.000 0700- 1- 31 Single Post Sign, f&i Bridge Mount Index 11870/700-012, Up To 12 Sf As 200.000 0700- 1- 32 Single Post Sign, f&i Bridge Mount Index 11870/700-012, 12-20 Sf As 100.000 0700- 1- 80 Single Post Sign, Repair As 300.000 0700- 1- 87 Single Post Sign, Repair- Replace Post, Use Existing Sign Panel As 300.000 0700- 2- 11 Multi- Post Sign, f&i Ground Mount, Up To 12 Sf As 200.000 0700- 2- 12 Multi- Post Sign, f&i Ground Mount, 12-20 Sf As 200.000 0700- 2- 13 Multi- Post Sign, f&i Ground Mount, 21-30 Sf As 100.000 0700- 2- 14 Multi- Post Sign, f&i Ground Mount, 31-50 Sf As 100.000 0700- 2- 15 Multi- Post Sign, f&i Ground Mount, 51-100 Sf As 50.000 0700- 2- 16 Multi- Post Sign, f&i Ground Mount, 101-200 Sf As 40.000 0700- 2- 17 Multi- Post Sign, f&i Ground Mount, 201-300 Sf As 40.000 0700- 2- 18 Multi- Post Sign, f&i Ground Mount, 301-400 Sf As 20.000 0700- 2- 50 Multi- Post Sign, Ground Mount, Relocate As 20.000 0700- 3-101 Sign Panel, Furnish & Install Ground Mount, Up To 12 Sf Ea 200.000 0700- 3-102 Sign Panel, Furnish & Install Ground Mount, 12-20 Sf Ea 200.000 0700- 3-103 Sign Panel, Furnish & Install Ground Mount, 21-30 Sf Ea 200.000 0700- 3-104 Sign Panel, Furnish & Install Ground Mount, 31-50 Sf Ea 200.000 0700- 3-105 Sign Panel, Furnish & Install Ground Mount, 51-100 Sf Ea 200.000 0700- 3-106 Sign Panel, Furnish & Install Ground Mount, 101-200 Sf Ea 200.000 0700- 3-107 Sign Panel, Furnish & Install Ground Mount, 201-300 Sf Ea 100.000 0700- 3-108 Sign Panel, Furnish & Install Ground Mount, 301-400 Sf Ea 100.000 0700- 3-109 Sign Panel, Furnish & Install Ground Mount, 401-500 Sf Ea 100.000 0700- 3-201 Sign Panel, Furnish & Install Overhead Mount, Up To 12 Sf Ea 50.000 0700- 3-202 Sign Panel, Furnish & Install Overhead Mount, 12-20 Sf Ea 30.000 0700- 3-203 Sign Panel, Furnish & Install Overhead Mount, 21-30 Sf Ea 40.000 0700- 3-204 Sign Panel, Furnish & Install Overhead Mount, 31-50 Sf Ea 40.000 0700- 3-205 Sign Panel, Furnish & Install Overhead Mount, 51-100 Sf Ea 40.000 0700- 3-206 Sign Panel, Furnish & Install Overhead Mount, 101-200 Sf Ea 40.000 0700- 3-207 Sign Panel, Furnish & Install Overhead Mount, 201-300 Sf Ea 40.000 0700- 3-208 Sign Panel, Furnish & Install Overhead Mount, 301-400 Sf Ea 25.000 0700- 3-209 Sign Panel, Furnish & Install Overhead Mount, 401-500 Sf Ea 25.000 0700- 3-210 Sign Panel, Furnish & Install Overhead Mount, 501-600 Sf Ea 25.000 0700- 3-211 Sign Panel, Furnish & Install Overhead Mount, 601 Sf And Greater Ea 10.000 0700- 3-301 Sign Panel, Furnish & Install Single Post Bridge Mount Index 11870/700-012, Up To 12 Sf Ea 50.000 0700- 3-302 Sign Panel, Furnish & Install Single Post Bridge Mount Index 11870/700-012, 12-20 Sf Ea 50.000 0700- 3-401 Sign Panel, Install, Up To 12 Sf Ea 50.000 0700- 3-402 Sign Panel, Install, 12-20 Sf Ea 200.000 0700- 3-403 Sign Panel, Install, 21-30 Sf Ea 200.000 0700- 3-404 Sign Panel, Install, 31-50 Sf Ea 200.000 0700- 3-405 Sign Panel, Install, 51-100 Sf Ea 200.000 0700- 3-406 Sign Panel, Install, 101-200 Sf Ea 100.000 0700- 3-407 Sign Panel, Install, 201-300 Sf Ea 50.000 0700- 3-408 Sign Panel, Install, 301-400 Sf Ea 50.000 0700- 4-111 Overhead Static Sign Structure, Furnish & Install, Cantilever, Up To 20 Ft Ea 20.000 0700- 4-112 Overhead Static Sign Structure, Furnish & Install, Cantilever, 21-30 Ft Ea 20.000 0700- 4-113 Overhead Static Sign Structure, Furnish & Install, Cantilever, 31-40 Ft Ea 10.000 0700- 4-114 Overhead Static Sign Structure, Furnish & Install, Cantilever, 41-50 Ft Ea 10.000 0700- 4-121 Overhead Static Sign Structure, Furnish & Install, Span, Up To 20 Ft Ea 10.000 0700- 4-122 Overhead Static Sign Structure, Furnish & Install, Span, 21-30 Ft Ea 10.000 0700- 5- 11 Internally Illuminated Sign, Furnish & Install Ground Mount, Up To 12 Sf Ea 50.000 0700- 5- 21 Internally Illuminated Sign, Furnish & Install Overhead Mount, Up To 12 Sf Ea 200.000 0700- 5- 22 Internally Illuminated Sign, Furnish & Install, Overhead Mount, 12-18 Sf Ea 200.000 0700- 11-121 Electronic Display Sign, Furnish & Install Ground Mountac Powered, Electronic Regulatory Sign, Up To 12 Sf As 50.000 0700- 11-321 Electronic Display Sign, Furnish & Install Overhead Mount- Ac Powered, Regulatory Sign, Up To 12 Sf As 50.000 0700- 12- 11 Sign Beacon, f&i Ground Mount- Ac Powered, One Beacon As 50.000 0700- 12- 12 Sign Beacon, f&i Ground Mount- Ac Powered, Two Beacons As 50.000 0700- 12- 21 Sign Beacon, f&i Ground Mount- Solar Powered, One Beacon As 50.000 0700- 12- 22 Sign Beacon, f&i Ground Mount- Solar Powered, Two Beacons As 50.000 0700- 12- 31 Sign Beacon, f&i Overhead Mount, One Beacon As 25.000 0700- 12- 32 Sign Beacon, f&i Overhead Mount, Two Beacons As 25.000 0700- 12- 60 Sign Beacon, Remove Beacon- Sign To Remain As 25.000 0705- 10- 1 Object Marker, Type 1 Ea 200.000 705- 10- 2 Object Marker, Type 2 Ea 200.000 0705- 10- 3 Object Marker, Type 3 Ea 200.000 0705- 11- 1 Delineator, Flexible Tubular Ea 500.000 0705- 11- 2 Delineator, Non-Flexible Ea 200.000 0705- 11- 3 Delineator, Flexible High Visibility Median Ea 200.000 0705- 11- 4 Delineator, Flexible High Performance 48" Ea 200.000 e700- 46- 32 Repair Existing Sign (Multi Post) As 300.000 |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |