Similar Projects
Range Hood Cleaning
Design
Fort Drum, NY

Utility Monitoring and Control Systems
Post-Bid
Less than $2,100,000,000 est. value

Utility Monitoring and Control Systems
Post-Bid
Less than $2,100,000,000 est. value

Replace Heating System - Building 19
Results
$550,000 to $1,100,000 est. value
Bedford Hills, NY 10507

Foley AC-1 Replacement Project
Results
Albany, NY 12207

Taconic Furnace Maintenance and Emergency Service
Term Contract
Post-Bid

J--HVAC Water Chillers Annual Maintenance Service Syracuse VA Medical Center
Results
Syracuse, NY 13210

HVAC Upgrades - William Boyce Thompson School
Post-Bid
Yonkers, NY

J--Critical AC Service Canandaigua (VA-18-00150130)
Results
Canandaigua, NY 14424

HVAC Maintenance Services
Post-Bid
Briarcliff Manor, Tarrytown, NY

L23127 Nevaldine Sourth 133 Esports, Phase 2
Results
Canton, NY

Chemical Water Treatment and Cooling Tower Maintenance Program
Post-Bid
Yonkers, NY

Replacement Rooftop HVAC Units
Results
Kingston, NY

Memorial Library Chiller Replacement
Post-Bid
$360,000 est. value
Cortland, NY 13045

Village of Kiryas Joel Water Plant HVAC System Upgrades
Results
Monroe, NY

Last Updated 01/04/2019 03:31 PM
Project Title

Repair/Replace HVAC Controls, Rochester, NY

Physical Address View project details and contacts
City, State (County) Rochester, NY 14624   (Monroe County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $100,000 to $250,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description The contractor shall furnish all supervision, personnel, equipment, tools, transportation, and materials necessary which includes the repair of the loss of communications with the control system for the HVAC controls per the Statement of Work. Work also includes Contractor to remove the existing Johnson Controls plant controllers (To include Air Handling Unit-1, Air Handling Unit-2, Hot Water System, Chilled Water System, and OMS,) and replace with Honeywell Spyder Controllers (Or equivalent.) Contractor shall provide an open license Tridium JACE-8000 (Or equivalent) running open license Niagara AX3.x software as, at minimum, an Integration controller.
Details
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents