Similar Projects
HVAC Unit Replacement at Irmo High School
Bidding
Columbia, SC 29212

HVAC and Electrical Services
Term Contract
Post-Bid

Furnish and Deliver Annual Maintenance and Support for an APC/Schneider Cooling System, Pumps and In-Row Coolers
Post-Bid
Lexington, SC

Administration Building and Judicial Center Chiller Replacement
Results
Less than $240,140 est. value
Lexington, SC 29072

HVAC Unit
Results
Less than $11,051 est. value
Irmo, SC 29063

Purchase and Installation of a 110 Ton Trane or Carrier Chiller
Post-Bid
Lexington, SC

Trane HVAC Units
Results
West Columbia, SC 29169

HVAC Replacement
Post-Bid
$400,000 to $500,000 est. value
West Columbia, SC 29170

HVAC Unit
Results
$12,978 est. value
Chapin, SC 29306

HVAC Inspection and Preventative Maintenance Services
Post-Bid
West Columbia, SC 29170

HVAC Unit
Results
$26,820 est. value
Irmo, SC 29063

Columbia State Farmers Market Buildings HVAC Service and Repair
Term Contract
Post-Bid
West Columbia, SC 29172

New Carrier HVAC Units
Results
West Columbia, SC 29169

Replace HVAC Units and Some Duct Work at Police Department
Post-Bid
Irmo, SC

MDC Dehumidification System Replacement
Results
$150,000 to $200,000 est. value
West Columbia, SC 29170

Reported 04/01/2021 08:41 AM
Project Title

Riverside Water Treatment Plant HVAC Replacement

Physical Address View project details and contacts
City, State (County) West Columbia, SC   (Lexington County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status No Responses Submitted
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Providing materials and labor necessary for the replacement of the existing HVAC system at the the City’s Riverside Water Treatment Plant. The City’s Riverside Water Treatment Plant (Plant) is located at 406 Sunset Boulevard in West Columbia, South Carolina and is located along the Saluda River. The project includes the replacement of four existing ductless systems, wall mount heads, and condensers with one condenser runner 4 wall mount heads. The system must heat and cool the following: 1. Laboratory approximately 430 SF. 2. Office 1 approximately 200 SF. 3. Break Area approximately 275 SF. 4. Control Room approximately 300 SF. Contractor will be responsible for the removal and disposal of the existing ductless HVAC system. Installer to provide a minimum 1-year parts and labor warranty. As a minimum the equipment shall carry a 10-year compressor and 10-year Parts. Minimum performance requirements are provided below. Multi Zone Unit 1. Operate up to 4 individual units. 2. Minimum Seer Rating: 22 3. Operating Range: 14 to 115 (oF) 4. Cooling Capacity: 12,000 to 48,000 BTU/hW. 5. Heating Capacity: 12,000 to 54,000 BTU/hW. 6. Refrigerant Type: R401A. 7. Sound pressure (Outdoor Unit): 55 dB(A). 8. Airflow Rate (Heating/Cooling): 2,472 SCFM.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents