Similar Projects
Equipment Operation and Maintenance for The Central Energy Building, Naval Health Clinic, MCAS Cherry Point Nc
Design
Cherry Point, NC

Page Hall Renovation
Renovation, Alteration - 31,000 SF
Design
Raleigh, NC 27695

NCSU - HVAC Renovation Matsumoto Wing - Brooks Hall
Alteration
Bidding
$565,000 est. value
Raleigh, NC 27605

Gas Water Heater and HVAC Venting Replacements
Alteration
Bidding
Raleigh, NC 27604

HVAC Water Treatment
Term Contract
Post-Bid
Greensboro, NC 27401

Request for Proposal for HVAC and Electrical Design and Consulting Services Andrew Carnegie Library
Post-Bid
Salisbury, NC 28144

HVAC Repairs Rachel Freeman School of Engineering
Results
Less than $93,657 est. value
Wilmington, NC 28405

EMD Facility HVAC Upgrades
Results
Wilmington, NC

McEniry HVAC and IT Infrastructure Upgrades
Construction
$10,000,000 est. value
Charlotte, NC 28223

Clearwater Ceramics Center
Alteration
Construction
Concord, NC

Rockfish Elementary School HVAC and Window Replacement
Alteration
Bidding
Hope Mills, NC 28348

CTC Computer Room Air Conditioner
Term Contract
Post-Bid
Archdale, NC 27263

Administration Building AHU Replacement
Results
$276,915 est. value
Durham, NC 27701

DPS Burton Elementary School Boiler Replacement
Alteration
Bidding
Durham, NC 27701

Chiller Plant Replacement for Southern Elementary School
Post-Bid
Greensboro, NC 27406

Reported 01/22/2022 12:00 AM
Project Title

Chiller Repairs Multiple Buildings MCBCL MCAS NR

Physical Address View project details and contacts
City, State (County) Camp Lejeune, NC 28547   (Onslow County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Request for Proposals (RFPs)
Bids Due View project details and contacts
Estimated Value $1,000,000 to $5,000,000
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Chiller Repairs General Description: 1. M130 50 ton chiller. 208/230 volt. Disconnect is 400 amp 250 volt. 2. BLDG 66 50 ton chiller. 208/230 volt. Disconnect is located on back side of building near chiller. 3. BLDG 10 is 65 ton chiller.460volt. Disconnect is 200 amp 600 volt. 4. BLDG 6 is 65 ton chiller.208/230 volt. Disconnect is 400 amp 240 volt. 5. H24 is 50 ton chiller. 208/230 volt. Breaker for chiller is located by chiller in panel. 6. BB12 is a 75 ton chiller. 208/230 volt. Disconnect is 400 amp 240 volt. 7. BB2 is a 70 ton chiller. 460 volt. Disconnect is 200 amp 600 volt. 8. RR2 is a 75 ton chiller. 208/230volt. Disconnect is a 400 amp 600 volt. 9. AS4004 is a 100 ton chiller.208/240 volts. Disconnect is a 600 amp 240 volt. 10. BB11 is a 70 ton chiller. 208/240 volts. Disconnect is a 400 amp 240 volt.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents