Similar Projects
Central Dispatch Carpet Replacement Services
Renovation
Sub-Bidding
$100,000 CJ est. value
Allegan, MI 49010

Carpet and Vinyl Tile Replacement - Health Department
Renovation
Sub-Bidding
$74,000 CJ est. value
Grand Rapids, MI 49503

Flooring Project
Post-Bid
Romulus, MI

Sandusky Elementary School - Gym Flooring
Renovation
Post-Bid
Sandusky, MI 48471

Repair Floors Base Wide
Term Contract
Results
$500,000 to $1,000,000 est. value
Battle Creek, MI 49037

Replace Ceiling Grid and Tiles
Alteration
Results
Warren, MI 48089

Carpet/Vinyl Installation
Alteration
Post-Bid
Grand Rapids, MI

Carson City Correctional Facility Food Service Flooring Replacement
Alteration
Results
Carson City, MI 48811

Carpeting
Alteration
Post-Bid
Grand Rapids, MI

Mortuary Science Flooring Replacement - 2022
Alteration
Results
$500,000 est. value
Detroit, MI 48202

Carpet Replacement
Alteration
Post-Bid
Lansing, MI 48911

Carpet Projects
Alteration
Results
Wayland, MI 49348

Item 98 - Resinous Flooring
Alteration
Post-Bid
Flint, MI

High School Gym Floor Refinishing and Ceiling Painting
Alteration
Results
Richland, MI 49083

2022 Flooring Replacement and Polishing
Term Contract, Alteration
Post-Bid
Troy, MI 48083

Last Updated 04/16/2023 08:01 AM
Project Title

Hangar 661 Concrete Floor Repair and Replacement Sawyer International Airport

Physical Address View project details and contacts
City, State (County) Gwinn, MI 49841   (Marquette County)
Category(s) Single Trades
Sub-Category(s) Flooring
Contracting Method Competitive Bids
Project Status Results, Construction start expected April 2023
Bids Due View project details and contacts
Estimated Value $41,800 [brand] Estimate
Plans Available from Agency's Affiliate
Owner View project details and contacts
Architect View project details and contacts
Description

The County requests quotes to repair/replace multiple sections of the concrete hangar floor in Hangar 661. See attachment 1 for approximate locations. The depth of the concrete in these sections must be replaced full-depth. All replacement concrete needs to be doweled/pinned into the existing concrete and re-barred. See attachment 2 for installation requirements. The strength of the concrete must be at minimum 5000psi. March 17, 2023 Questions Due from Bidders

Details

Division 09 - Finishes, Flooring.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents